The Navien PeakFlow® A System is a scale prevention system designed to protect tankless water heaters from scale build-up on the inner pipe surfaces of their heat exchangers. It operates as a salt-free system, utilizing a media cartridge to prevent scale formation without adding salt to the water.
The primary function of the PeakFlow A System is to prevent the accumulation of scale, which can degrade the efficiency and lifespan of tankless water heaters. It achieves this by treating the incoming water to mitigate scale-forming minerals. The system is designed for installation in the water supply line leading to the tankless water heater. It is crucial to ensure proper water flow direction during installation, following the arrow indicated on the system's head. The system is intended for use with specific feed water chemistry, and certain contaminants or water treatment methods must be avoided for optimal performance and to maintain warranty validity. For instance, it cannot be used in conjunction with polyphosphate or other scale inhibitors, and polyphosphate must be removed from the feed water before the PeakFlow A System. Similarly, oil and H2S must be removed. The system does not reduce silica scaling, and while silica has a less significant effect on scale formation, it can act as a binder for water spots and residue.
The PeakFlow A System requires careful installation to ensure proper operation and to avoid damage or injury. It must be installed vertically, upright, and level, secured to a wall stud or an appropriate spanning area. When connecting water supply lines, 2-3 wraps of Teflon® tape should be used on threaded connections, and liquid pipe compounds should be avoided. Overtightening connections is also cautioned against. After installation, it is recommended to let water flow through the system for two minutes at the specified flow rate to allow air bubbles to escape, especially if a drain valve is not present on the outlet side. The system should not be exposed to freezing temperatures; if temperatures drop below 40°F, the water supply to the housing should be shut off and the housing drained. Direct sunlight and exposure to strong chemicals or physical impact from equipment, carts, or mops should be avoided. If a water hammer is present in the plumbing system, a water hammer arrestor should be installed in front of the PeakFlow A System. The system is not to be used with microbiologically unsafe water.
The PeakFlow A System is designed for straightforward maintenance, primarily involving the replacement of its scale prevention media.
| Brand | Navien |
|---|---|
| Model | PeakFlow A |
| Category | Water Filtration Systems |
| Language | English |
Loading...