15
I403 PROGRAM MODE
=1, the NC is in program-editing mode
=0, no PROGRAM mode
I404 TEST MODE
=1, the NC is in program test mode
=0, no TEST mode
I405 AUTO MODE
=1, the NC is in automatic program execution mode
=0, no AUTO mode
I407 JOG STATE
=1 the NC is in an operational mode where the use of jog buttons or the use of the
handle is allowed.
=0 not JOG state
I410 STOP STATE
=1, the NC STOP lamp is on
=0, the NC STOP lamp is off
I411 START STATE
=1, the NC START lamp is on
=0, the NC START lamp is off
I412 MACHINE ON button
0 $
$$
$ 1 when the MACHINE ON button is pressed
1 $
$$
$ 0 when the PLC acknowledges this by the instruction U401
I417 state of part counter
=1 the value of the part counter has reached the value specified on parameter
PRTOTAL. This flag is 1 at most for 100 msec after this event.
=0 the value of the part counter hasn`t reached the value specified on parameter
I440 Output of MON disable
=1, MACHINE ON cannot be issued (disastrous machine trouble)
=0, MACHINE ON can be output
I450 run of set-point signal "S" completed
=1, set-point signal "S" has assumed the nominal value (N=N
S
)
=0, run of set-point signal "S" is on (NUN
S
)
I460 selection of external handwheel axis
=1, selector in position 1
I461 selection of external handwheel axis
=1, selector in position 2
I462 selection of external handwheel axis
=1, selector in position 3