EasyManua.ls Logo

NDB Technologie XDP-II User Manual

NDB Technologie XDP-II
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
XDP-II User’s Guide
NDB Technologie Inc. 02/04/08 1
PARTIAL
DISCHARGE DETECTOR
XDP-II
User’s Guide
Version 7.2
March 2009
NDB Technologie Inc.
1405 St-Jean Baptiste St., suite 111
Québec, QC
G2E 5K2, Canada
Phone: (418) 877-7701
Fax: (418) 877-7787
http://www.ndbtech.com
Question and Answer IconNeed help?

Do you have a question about the NDB Technologie XDP-II and is the answer not in the manual?

NDB Technologie XDP-II Specifications

General IconGeneral
BrandNDB Technologie
ModelXDP-II
CategorySecurity Sensors
LanguageEnglish

Summary

Introducing the XDP-II

Partial Discharges

Explains the phenomenon of partial discharges and their effect on insulating materials.

The XDP-II

Introduces the XDP-II device and its primary function in detecting partial discharges.

Applications

Lists the various types of equipment and scenarios where the XDP-II can be applied.

Product Overview

Equipment and Accessories

Details the standard components provided with the XDP-II unit.

XDP-II Overview

Provides a detailed breakdown and labeling of the XDP-II device's physical components.

Calibration Check

Calibration Check Procedure

Outlines the steps to perform a calibration check using the XDP-302 capacitive sensor.

XDP-II Main Functions and Modes

Menus and Modes Overview

Introduces the device's menu structure and available operating modes like SAVE, MODE, FILE, and PARAMETERS.

Peak-Angle Mode

Explains the Peak-Angle mode for displaying PD by synchronizing with line frequency.

Analysis Mode

Details the Analysis mode for comparing acquired signals with a signature database.

Edge Mode

Describes the Edge mode for accurate graphic display of PD signal edges.

Applications

XLPE/EPR Cable Splice & Elbow PD Check

Guide for checking partial discharges on XLPE/EPR cable splices and elbows.

Filters

Information on using filters to eliminate outside noises during measurements.

Off-line PD Test Kit (Variable Transformer)

Step-by-step guide for performing off-line PD tests with a variable transformer.

Off-line PD Test Kit (PD Free Source)

Procedure for calibrating and measuring PD using a PD-free source.

Switchgears

How to use the XDP-II with switchgear couplers for PD detection.

Technical Specifications

XDP-II Characteristics

Lists the technical features and capabilities of the XDP-II device.

Batteries

Instructions on recharging the XDP-II batteries.

Specifications

Comprehensive technical specifications including resolution, range, bandwidth, and dimensions.