problem
potential causes
some unexpected Electronic
device malfunction
service battery high voltage
(higher then 15V)
Solution
we suggest to avoid the desulphation phase selecting the C o D
charging curve.
problem
potential causes
the alternator led flash 6 times
detected voltage drop on the
alternator
alternator insufficient power
power component overheating
power loss on the cables
Solution
1. cables must have 10mm
2
(min) section.
2. check the connections on terminals 1,2,3 and 6.
3. connect the cable attached to terminal 1 directly to the negative
pole of the engine battery (or services),
4. cable attached to terminal 2 directly to the negative pole of the
service battery (or motor),
5. the cable relative to terminal 3 to the positive pole of the engine
battery, or positive pole of the alternator
6. the cable relative to terminal 6 to the positive pole of the service
battery.!
"
in case of overheating of the power components of the
electronic board, the system automatically reduces the
current supplied for charging, until the alarm returns.