With battery voltage equal to Vmax (Maximum
voltage of the selected charging curve), will be
delivered a costant voltage equal to the
selected curve Vmax. The delivered current will
decrease as the battery state of charge
increases till about 3A. Timeout 6 hours.
An approximately 2A constant current will be
delivered, allowing the battery voltage to rise
independently to the maximum value of 15.8V.
This phase ends to the achievement of 15.8V.
Timeout 2 hours.
This phase keep a constant voltage related to
the selected charging curve (Vmaint). This phase
has a 4 hours timeout for the LiFePO
4
charging
curve with maintenance ON (curve N°7), while
for the other curves there’s no time limit. If
during the maintenance phase the voltage
should fall below 13.15V for LiFePO
4
curve and
12.65V Wet curve and 12.8V and for the other
curves, charge will be restarted from the first
phase. Timeout 4 hours.
With voltage between 8V and 10.5V, a variable
current between 1A and 2A, every 5 seconds.
Timeout 4 hours.
With voltage between 10.5V and 12.0V, an
approximately 2A costant current will be delivered.
Timeout 8 hours.
With battery voltage between 12V and 14,4V,
will be delivered a 5A constant current.
With battery voltage 14,4V will be delivered a
14,4V constant voltage. The delivered current will
decrease as the battery state of charge increases
till about 3A. Timeout 6 hours.
This phase keep a constant voltage of 13,5V.
Timeout 8 hours.