Extron System 4
xixi
xixi
xi
Switcher Series Users Manual P/N 68-413-02 Rev. E
Configuration and ConnectionsNEC Installation
Page 11
(Note: Information depends on
S
y
stem 4
x
i
setup.
)
(See note.)
(See note.)
(See note.)
(See note.)
[System 4
xi
model and software
version displayed here]
Connecting System 4
xixi
xixi
xi to NEC XT 5000 (or equivalent) Projector
If the System 4xi is already configured for an NEC XT 5000 projector, go to step
4. If it is not set up correctly, it will be necessary to change switch settings on the
System 4xi s Main Controller Board. Begin at Step 1 to verify the correct
configuration.
1. Use the Front Panel to display the Information Menu to verify that the System 4xi
is already set up for the NEC XT 5000 projector. Apply power to the System 4xi
and do the following:
a. Press to display the MENU SELECT on the LCD screen.
b. Press or to step to Menu 8.
c. Press to select this menu.
d. Press or to display the configuration. The example to the left is general,
yours will show the System 4xi model name, the software version and the
following information:
PRJ = NEC 10XX
PRJ BAUD = 38400
UNIT No. = 000
HST BAUD = 9600 (value depends upon setup Menu 3)
2. Go to the procedure on page 2-3 to remove the System 4xi cover and then go to
page 2-4 to set up the Main Controller board. Return to Step 3 (below) when the
configuration is correct.
Config Projector SW1: 1-2-3-4 SW2 SW3 SW4 SW5 SW6 Prj Cable Comm
as Adapter
NEC XT 5000 (host control) off-on-on-off 0 0 5 E 0 J15 26-467-01
3. Double-check your work and be sure the System 4xi cover is on securely.
4. Install the System 4xi in its place of operation (i.e. rack), but not powered on.
__________ Changes in some switch configurations are not detected until the power is
removed at the AC cord, and then restored.
If the Projector Cable is wrongly connected to J9 on the Main Controller Board,
Menu 8 will not indicate the error.
Use the following connection diagram and continue.