EasyManuals Logo

NEC MultiSync V423 User Manual

NEC MultiSync V423
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
(25/72)
Readout value is 2's complement.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 Check code for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Readout value
Temperature [Celsius]
Binary Hexadecimal
+125.0 0000 0000 1111 1010
00FAh
+ 25.0 0000 0000 0011 0010
0032h
+ 0.5 0000 0000 0000 0001
0001h
0 0000 0000 0000 0000
0000h
- 0.5 1111 1111 1111 1111
FFFFh
- 25.0 1111 1111 1100 1110
FFCEh
- 55.0 1111 1111 1001 0010
FF92h