46
Technician menu - Summary
0404 211 - 02
CONFIRM DATA/
CONFIRM FUNCTION
DELETE DATA/
EXIT FUNCTION
PREVIOUS FUNCTION/
DECREASE DATA UNIT (-1)
NEXT FUNCTION/
INCREASE DATA UNIT (+1)
TECH >2.3.1
Temperature
TECH >2.3.3
Enable cold unit
TECH >2.3
Cold parameters
Operating temperature
5°C to 20°C.
8°C by default
Internal temperature
Temp. °C =
##
TECH >2.3.2
Defrosting
Defrosting interval
0 to 99 hours
6 hours by default
Defrosting inter.
Defr. inter. =
##
ON/OFF
Enable cold unit
Food models
2°C to 20°C.
8°C by default
TECH >2.3.4
Enable Food control
ON/OFF
Enable Food control
Enable tray ##
ON/OFF
TECH >2.3.5
Temperature log
Sample ###
##.##.## ##.## ##
Trays 4 to 6
0 to 143 samples.
Reading
Date
Time
Temperature