Strain relief & cover
Make sure all cables are properly secured
and the protection cover is placed back
over the terminals.
Power ON
Make sure to close the enclosure before
connecting the AC mains.
If powered devices are not working properly
please check if the DC output is 13.2 V.
The DC output can be adjusted with the
Voltage adjuster.
AC mains input
-V +V
Live
(brown)
AC mains
Neutral
(blue)
L N
3 x 0.75 m, earth connection, max. 2 m
Make sure that the AC mains (230-240 VAC)
is NOT connected!
Shield & earth
-V +V
Shield
AC mains DC output
Earth wire
(green-yellow)
The protective earth wire should be the
last to disconnect in the event of an
inadvertent pull on the power cord.
DC output
1
2
3
-V +V
GND Vin
DC output
2 x 0.5 mm
2
shielded, max. 5 m
Remove the protection cover from the
terminals before wiring.
A
B
DC outputAC mains input
Power LED
Voltage adjusterL N -V +V
Protection cover
13
2
5
4
5
Wiring specications
Purpose
A. AC mains input wiring
B. DC output wiring
Specification
3 x 0.75 mm², earth connection, max. 2 m
2 x 0.5 mm
2
shielded, max. 5 m
Failure to comply with the wiring specications may result in
malfunction and/or dangerous situations.
Instructions
Step
1.
2.
3.
4.
5.
DC output
Shield & earth
AC mains input
Strain relief & cover
Power ON
Remarks
Default output is 13.2 V.
Connect shield and earth wire at the same time to the same terminal.
Make sure the AC mains input is still disconnected at this point.
Use the available provisions to secure all cables.
Make sure the protection cover is put back over the terminals.
Before installing or servicing this device
please read and take the Safety precautions
into account. These can be found on the
backside of this installation guide.
Conductors connected to the screw
terminals must be tted with a ring,
crimped lugs, etc. so that reliance is not
placed upon the screw alone.
Question and Answer IconNeed help?

Do you have a question about the Nedap AEOS Blue AP7021 and is the answer not in the manual?

Summary

Instructions and Wiring

DC Output Connection

Details for connecting the DC output, including voltage specifications.

Shield and Earth Wiring

Instructions for correctly connecting shield and earth wires for safety.

AC Mains Input Connection

Guidelines for connecting the AC mains power supply safely and correctly.

Cable Management and Cover

Procedures for securing cables with strain relief and replacing the protection cover.

Power On Procedure

Steps to follow for safely powering on the device after installation.

Mounting and Enclosure

Mounting Specifications

Dimensions, drill patterns, and DIN rail mounting information.

Opening the Enclosure

Step-by-step instructions on how to open the device enclosure safely.

Technical Specifications and Safety

Technical Specifications Overview

Lists key technical details like dimensions, power, and environmental limits.

General Safety Precautions

Outlines essential safety guidelines for installation and operation.

Device Indicators and Certifications

Power LED Status

Explanation of the internal Power LED indicator's function.

Compliance Certifications

Information regarding the device's compliance with relevant directives.

Overview

The AEOS Blue power supply 12V, model AP7021 (part number 5283507), is a Class I device designed to provide a stable 12V DC output for various applications. This installation guide, dated March 19, 2020, outlines the necessary steps for safe and proper installation, operation, and maintenance of the device.

Function Description

The primary function of the AP7021 is to convert AC mains power into a regulated 12V DC output. It serves as a power source for devices requiring a 12V DC supply, ensuring reliable operation within a specified range of environmental conditions. The device is equipped with a Power LED (internal) that illuminates green when the DC output is active, providing a visual indication of its operational status.

Important Technical Specifications

Dimensions and Weight:

  • Dimensions: 230 x 165 x 65 mm (H x W x D)
  • Weight: Approximately 820 g
  • Enclosure: PC ABS material

Electrical Specifications:

  • AC Mains Input: 230-240 VAC, 50/60 Hz, 1.2 A
  • DC Output: 13.2 VDC SELV, 4.5 A (Default output is 13.2 V, adjustable via a voltage adjuster)
  • AC Mains Input Wiring: 3 x 0.75 mm², earth connection, maximum 2 m
  • DC Output Wiring: 2 x 0.5 mm² shielded, maximum 5 m

Environmental Conditions:

  • Operation Temperature Range: 0°C to 40°C
  • Storage Temperature Range: -30°C to 65°C
  • Relative Humidity: 20% to 90% (non-condensing)

Certifications: The AP7021 is tested and conforms with essential requirements of:

  • Electromagnetic Compatibility Directive 2004/108/EC: EN50130-4 (2011), EN55022 (2010) + AC(2011)
  • Low Voltage Directive 2006/95/EG: EN60950-1 (2006) + A11(2009) + A1(2010) + A12(2011) + AC(2011) + A2(2013)

Usage Features

Installation: The device can be mounted using a DIN rail 35 x 7.5 mm or by drilling three Ø5 mm holes according to the provided drill pattern (120 mm horizontal spacing, 113.5 mm vertical spacing, with the top two holes 12.5 mm from the top edge). Preferred screws are 4.8 x 32 mm (DIN7981).

Wiring:

  • DC Output (Step 1): Remove the protection cover from the terminals before wiring. Connect 2 x 0.5 mm² shielded wires, maximum 5 m. The default output is 13.2 V.
  • Shield & Earth (Step 2): Connect the shield and earth wire at the same terminal simultaneously. The protective earth wire should be the last to disconnect in case of an inadvertent pull on the power cord.
  • AC Mains Input (Step 3): Ensure the AC mains (230-240 VAC) is NOT connected during this step. Connect 3 x 0.75 mm² wires for live (brown), neutral (blue), and earth connection, maximum 2 m. Conductors connected to screw terminals must be fitted with a ring, crimped lugs, etc., to ensure secure connections.
  • Strain Relief & Cover (Step 4): Secure all cables properly using the available provisions and place the protection cover back over the terminals.
  • Power ON (Step 5): Ensure the enclosure is closed before connecting the AC mains. The Power LED will illuminate green when the DC output is active.

Voltage Adjustment: The DC output can be adjusted using the voltage adjuster if powered devices are not working properly and the default 13.2 V output needs fine-tuning.

Maintenance Features

Safety Precautions:

  • Qualified Personnel: This equipment should only be installed, operated, serviced, and repaired by qualified personnel familiar with applicable standards and codes.
  • Power Supply Matching: Ensure the source voltage matches the power supply's voltage before turning ON the power.
  • Power Cord and Plug: Use a maximum 4.5 m long, rated minimum 250 V, 10 A, Type SJT flexible cord with a 10 A, 240 V 3-pole grounding attachment plug (CE approved). The socket-outlet must be near the equipment and easily accessible.
  • Fixed Power Connection: If connected to fixed mains, a disconnect from mains must be available near the equipment.
  • Protective Grounding: The protective grounding terminal must be connected to ground to prevent electric shock before powering ON.
  • Fuse Replacement: For continued protection against fire, replace fuses only with the same type and rating. Turn off power and disconnect the power source before replacing fuses. Do not use a different fuse or short-circuit the fuse holder.
  • Flammable Materials: Do not operate the equipment near flammable liquids or vapors.
  • Opening Covers: Do not open the top cover when active due to lethal voltages. Always disconnect from mains supply and ensure safety before maintenance.
  • No Modification: Do not modify or add anything to the equipment other than what is mentioned in this installation guide or indicated by NEDAP NV.

Troubleshooting: If powered devices are not working properly, check if the DC output is 13.2 V. The DC output can be adjusted with the voltage adjuster. Failure to comply with wiring specifications may result in malfunction and/or dangerous situations.

This device is designed for guidance, and while the publisher assumes no liability for its use, specifications and availability are subject to change without notice. Reproduction of this document, in whole or in part, without written consent from the publisher is prohibited.

Nedap AEOS Blue AP7021 Specifications

General IconGeneral
BrandNedap
ModelAEOS Blue AP7021
CategoryPower Supply
LanguageEnglish