EasyManua.ls Logo

nedis AIPU100CWT - Page 6

nedis AIPU100CWT
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
Troubleshooting
Problem Solution
The product does not
switch on.
Connect to a power outlet.
Check if the power cord is damaged.
Make sure A
7 is closed.
The product is making
strange noises.
Make sure A
6 is placed in the correct way.
Press B
4 to increase the speed
Replace A
6.
Poor purication quality. Do not block ventilation openings and make sure
that there is enough space around the product.
Make sure A
6 is placed in the right way.
Make sure the room is smaller than 20 m
2
.
Replace A
6.
The product spreads an
unpleasant odour.
Make sure the room has a relative humidity
below 85 %.
Replace A
6.
B
8 illuminates after
replacing A
6.
Press and hold B
8 for 3 seconds to reset.
Specications
Product Air purier
Article number AIPU100CWT
Dimensions (l x w x h) 215 Ø x 460 mm
Applicable area < 20 m
2
Clean air delivery rate 200 m
3
/ h
Noise level 32 - 50 dB
Operating temperature -10 °C - 40 °C
Operating humidity < 95 % RH
Power supply 220 - 240 VAC ~ 50 / 60 Hz
Rated power 35 - 40 W
Standby power < 0.5 W