The product can also be installed on a sloped ceiling.
-
Do not install in the tip of a sloped ceiling as smoke-free air can collect in
these areas, preventing smoke from reaching the product.
In sleeping areas:
• Not in turbulent air (near windows, ceiling fans or air conditioners).
• Not behind objects (curtains or closets).
Other areas:
• Not in turbulent air (near windows, ceiling fans or air conditioners).
• Not behind objects (curtains or closets).
4
For optimal smoke detection install the product at a minimal height of 1.80 m.
Do not install the product:
• in dirty, greasy or dusty areas.
• in temperatures below -10 ºC.
• in temperatures above 55 ºC.
• in turbulent air (near ceiling fans, air conditioners or open windows).
• within 3 meters of a high humidity source.
• within 1.5 meters of kitchen appliances.
• within 6 m of a furnace or fuel burning heat sources.
• behind objects like curtains or closets.
• within 1 m of uorescent light.
Installing/Mounting the product (image C & D)
1. Place the bracket A
5
in the desired location.
Follow steps 2. - 6. for stone/concrete surfaces. Continue to step 5. for wood
surfaces.
2. Use the bracket A
5
to mark the drill locations with a pencil.
3. Drill two Ø 4 mm holes.
4. Insert the plugs A
8
into the holes.
5. Fasten the bracket A
5
with the screws A
7
.