SPECIFICATION DIAGRAMS – COMPACT APPLIANCES
Note: Intermediate shelf required
if installed directly above any other
appliance, alternatively the Z11SZ90X0
SeamlessCombination kit or the
Z11SZ00X0 SeamlessCombination
LQVHUWLRQÁRRUFDQEHXVHGLQSODFHRI
the intermediate shelf.
12768,7$%/()25,167$//$7,21
%(/2:27+(5$33/,$1&(6,1$
:$//02817('&$%,1(7
min 35mm
All descriptions and technical diagrams are intended as a guide only. For additional technical information, full dimensional and installation
details, please refer to the instruction and installation manuals supplied with the appliance, which can be accessed on-line for your
SODQQLQJSXUSRVHVYLDZZZQHɡFRQ]$OOPHDVXUHPHQWVDUHLQPP
Note: Intermediate shelf required if installed directly above any other appliance, alternatively the Z11SZ90X0 SeamlessCombination kit
RUWKH=6=;6HDPOHVV&RPELQDWLRQLQVHUWLRQÁRRUFDQEHXVHGLQSODFHRIWKHLQWHUPHGLDWHVKHOI
In order to prevent appliances
from overheating and to ensure
that they cool down as required
after operation, appropriate
minimum cross sections of free
space must be maintained from
kitchen furniture.
$//&203$&729(16²&)6+%&)7+%&06+%$1'&051%
$'',7,21$/',$*5$0)25)8//67($0&203$&729(16²&)6+%$1'&)7+%
All descriptions and technical diagrams are intended as a guide only. For additional technical information, full dimensional and installation
details, please refer to the instruction and installation manuals supplied with the appliance, which can be accessed on-line for your
SODQQLQJSXUSRVHVYLDZZZQHɡFRQ]$OOPHDVXUHPHQWVDUHLQPP
If the appliance will be installed underneath
a cooktop, the following worktop thicknesses
(including substructure if necessary) must be
taken into account.
Cooktop type Minimum worktop thickness
Induction 42mm
Gas 37mm
Electric 28mm
$//&203$&729(16²&)6+%&)7+%&06+%$1'&051%
QHɡFRQ] QHɡFRQ]