General information en
15
:Warning – Risk of electric shock!
Components inside the appliance may have
sharp edges. These may damage the
connecting cable. Do not kink or pinch the
connecting cable during installation.
Risk of electric shock!
It must always be possible to disconnect
the appliance from the electricity supply.
The appliance must only be connected to a
protective contact socket that has been
correctly installed.
The mains plug of the mains power cable
must be easily accessible after installation
of the appliance. If this is not possible, an
all-pole isolating switch must be integrated
into the permanent electrical installation
according to the conditions of overvoltage
category III and according to the installation
regulations.
The permanent electrical installation must
only be wired by a professional electrician.
We recommend installing a residual-current
circuit breaker (RCCB) in the appliance's
power supply circuit.
:Warning – Risk of electric shock!
Incorrect repairs are dangerous. Repairs may
only be carried out and damaged power
cables replaced by one of our trained after-
sales technicians. If the appliance is defective,
unplug the appliance from the mains or switch
off the circuit breaker in the fuse box. Contact
the after-sales service.
:Warning – Danger of suffocation!
Packaging material is dangerous to children.
Never allow children to play with packaging
material.
KGeneral information
Gener al informat i on
Exhaust air mode
:Warning – Risk of death!
Risk of poisoning from flue gases that are drawn back
in. The exhaust air must not be conveyed into a
functioning smoke or exhaust gas flue or into a shaft
which is used to ventilate installation rooms that contain
heating appliances. If the exhaust air is to be conveyed
into a non-functioning smoke or exhaust gas flue, you
must obtain the consent of the heating engineer
responsible.
If the exhaust air is conveyed through the outer wall, a
telescopic wall box should be used.
Exhaust duct
Note: The device manufacturer does not assume any
warranty for complaints attributable to the pipe section.
The device achieves its optimum performance by
means of a short, straight exhaust air pipe and as
large a pipe diameter as possible.
As a result of long rough exhaust air pipes, many
pipe bends or pipe diameters that are smaller than
150 mm, the optimum extraction performance is not
achieved and fan noise is increased.
The pipes or hoses for laying the exhaust air line
must consist of non-combustible material.
Round pipes
An inner diameter of 150 mm, but at least 120 mm, is
recommended.
Flat ducts
The inner cross-section must correspond to the
diameter of the round pipes.
dia. 150 mm ca. 177 cm
2
dia. 120 mm ca. 113 cm
2
Flat ducts should not have any sharp deflections.
Use sealing strips for deviating pipe diameters.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEFF D95BMP5N0 and is the answer not in the manual?

NEFF D95BMP5N0 Specifications

General IconGeneral
Current10 A
Motor power140 W
Connected load145 W
AC input voltage220-240 V
AC input frequency50 - 60 Hz
Annual energy consumption34 kWh
Noise level55 dB
Intensive speedYes
Number of speeds3
Type of extractionDucted/Recirculating
Noise level (low speed)45 dB
Maximum extraction power702.1 m³/h
Maximum recirculating power378 m³/h
Minimum distance from gas hob650 mm
Noise level (intensive speed)66 dB
Noise level (recirculation mode)73 dB
Grease filtering efficiency classB
Minimum distance from electric hob550 mm
Bulb typeLED
Bulb power1.5 W
Illuminance373 lx
Number of bulbs3 bulb(s)
Lighting positionFront
Grease filter typeStainless steel
TypeWall-mounted
Motor typeBrushless motor
Cord length1.3 m
Control typeTouch
CertificationCE, VDE
Product colorBlack, Stainless steel
Exhaust locationTop
Exhaust connection diameter150 mm
Weight and Dimensions IconWeight and Dimensions
Depth500 mm
Width898 mm
Weight19363 g
Height (max)1139 mm
Height (min)528 mm
Height without chimney46 mm