Control Type: Advanced
If you wanted to configure a Return pump to be on all the time except
during a feed mode and maintenance mode, then select “Advanced” option
in “Control Type”
Fallback ON
Set ON
If FeedA 000 Then Off
If FeedB 000 Then Off
Notes:
Any wizard can be switched to advance control type after updating the outlet
to add more
FeedA and FeedB have been configured to be 5 and 30 minutes long:
Display screen: Setup> Outlet Setup> Feed Interval> Select Feed> Feed
Interval
Control Type: Chiller
If you wanted to configure a chiller/fan in outlet #1 to control temperature
to 77 degrees. Select “Chiller” option in “Control Type”
On Temp: 78.0
Off Temp: 77.0