Do you have a question about the Net Safety UV/IRS-A and is the answer not in the manual?
Details the warranty duration for sensors and other electronic assemblies.
Provides company contact details including address, phone, fax, and website.
Explains the UV and IR wavelengths detected and immunity to other light sources.
Lists factors for optimal positioning of fire detectors based on fire characteristics.
Lists common environments and industries where the UV/IRS detector is deployed.
Identifies common hydrocarbon fuels that can act as ignition sources.
Discusses how UV absorbing gases can impact detector performance and detection.
Lists conditions and activities to which the UV/IRS detector shows immunity.
Provides guidelines for mounting and positioning detectors for optimal performance.
Details detector wiring requirements, conduit use, and cable specifications.
Emphasizes correct shielding and grounding procedures for safe installation.
Recommends conduit seals to prevent moisture ingress and maintain integrity.
Explains adjustment of detector sensitivity based on radiation intensity and flame conditions.
Describes the function of time delay for fire alarm signaling and its benefits.
Details DIP switch settings for fire relay operation (latching/non-latching modes).
Explains how to reset the detector when configured for latching status.
Lists essential final checks and actions after detector installation and configuration.
Describes detector viewing windows and the optional heater function.
Outlines the detector's 90-second start-up routine and normal operation indicators.
Advises on performing system checks and disabling external equipment during testing.
Explains the meaning of the detector's status indicator LEDs.
Highlights the need for periodic checks to ensure maximum detector sensitivity.
Provides steps for manually verifying detector obstruction and VI circuit function.
Describes the automatic VI test and its role in detecting obstructions or faults.
Details steps for performing a manual VI test and interpreting the results.
Explains the function and inspection of the detector's o-ring for watertightness.
A guide to identifying and resolving common false alarm conditions and detector faults.
Lists potential causes for various detector operational issues and fault indicators.
Provides recommended actions and solutions for troubleshooting detector problems.
| Sensor Type | UV/IR flame detector |
|---|---|
| Humidity | 0 to 95% RH, non-condensing |
| Enclosure | Stainless steel |
| Enclosure Rating | IP66/67 |
| Detection Principle | Ultraviolet and Infrared Sensing |
| Detection Range | Up to 30 meters |
| Field of View | 90 degrees horizontal |
| Operating Temperature | -40°C to +75°C (-40°F to +167°F) |
| Power Supply | 18-30 VDC |
| Outputs | 4-20 mA |
| Approvals | FM, ATEX, IECEx, CSA |
| Response Time | ≤ 5 seconds |