The new license keys that you require are automatically generated and sent to the email
address on file. If you fail to receive the email with the license keys within 30 days, you
should contact technical support.
2.
Install each license key:
system license add -license-code license-key, license-key...
3. Remove the old licenses, if desired:
a.
Check for unused licenses:
license clean-up -unused -simulate
b.
If the list looks correct, remove the unused licenses:
license clean-up -unused
Step 2: Verify LIFs and registering the serial number
Before returning the replacement node to service, you should verify that the LIFs are on their home ports, and
register the serial number of the replacement node if AutoSupport is enabled, and reset automatic giveback.
Steps
1.
Verify that the logical interfaces are reporting to their home server and ports:
network interface show
-is-home false
If any LIFs are listed as false, revert them to their home ports: network interface revert -vserver
* -lif *
2. Register the system serial number with NetApp Support.
◦ If AutoSupport is enabled, send an AutoSupport message to register the serial number.
◦ If AutoSupport is not enabled, call NetApp Support to register the serial number.
3.
If an AutoSupport maintenance window was triggered, end it by using the
system node autosupport
invoke -node * -type all -message MAINT=END
command.
4.
If automatic giveback was disabled, reenable it:
storage failover modify -node local -auto
-giveback true
Step 3: Return the failed part to NetApp
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Part Return
& Replacements
page for further information.
Replace a DIMM - AFF A250
You must replace a DIMM in the controller module when your system registers an
increasing number of correctable error correction codes (ECC); failure to do so causes a
system panic.
About this task
All other components in the system must be functioning properly; if not, you must contact technical support.
You must replace the failed component with a replacement FRU component you received from your provider.
Step 1: Shut down the impaired controller
To shut down the impaired controller, you must determine the status of the controller and, if necessary, take
282