You must enter Y when prompted to override the system ID due to a system ID mismatch.
2.
View the old system IDs from the healthy node:
`metrocluster node show -fields node-
systemid
,dr-partner-systemid`
In this example, the Node_B_1 is the old node, with the old system ID of 118073209:
dr-group-id cluster node node-systemid dr-
partner-systemid
Ê----------- --------------------- --------------------
------------- -------------------
Ê1 Cluster_A Node_A_1 536872914
118073209
Ê1 Cluster_B Node_B_1 118073209
536872914
Ê2 entries were displayed.
3.
View the new system ID at the Maintenance mode prompt on the impaired node:
disk show
In this example, the new system ID is 118065481:
Local System ID: 118065481
Ê ...
Ê ...
4. Reassign disk ownership (for FAS systems) or LUN ownership (for FlexArray systems), by using the
system ID information obtained from the disk show command:
disk reassign -s old system
ID
In the case of the preceding example, the command is: disk reassign -s 118073209
You can respond Y when prompted to continue.
5.
Verify that the disks (or FlexArray LUNs) were assigned correctly:
disk show -a
Verify that the disks belonging to the replacement node show the new system ID for the replacement
node. In the following example, the disks owned by system-1 now show the new system ID,
118065481: