8. After you have completed the initial configuration, go to the ONTAP & ONTAP System Manager
Documentation Resources
page for information about configuring additional features in ONTAP.
Maintain
Add an I/O module - AFF A900
You can add an I/O module to your system by either adding a new I/O nodule into a
system with empty slots or by replacing an I/O module with a new one in a fully-populated
system.
Before you begin
Check the
NetApp Hardware Universe to make sure that the new I/O module is compatible with your
system and version of ONTAP you’re running.
If multiple slots are available, check the slot priorities in
NetApp Hardware Universe and use the best one
available for your I/O module.
To non-disruptively add an I/O module, you must take over the target controller, remove the slot blanking
cover in the target slot or remove an existing I/O module, add the new or replacement I/O module, and then
giveback the target controller.
Make sure that all other components are functioning properly.
Option 1: Add the I/O module to a system with open slots
You can add an I/O module into an empty module slot in your system.
Step 1: Shut down the impaired node
Shut down or take over the impaired controller using one of the following options.