Safety instructions
- moving the overhead line,
- cabling or
- limiting the working range of earthmoving
machinery.
6.8.5 In the event of a voltage transfer, the following rules must be
observed:
- Do not leave the operator’s cab.
- Warn other persons not to approach or touch the machine.
- If possible, bring the operating device or the entire earthmoving machine out of the
hazard
zone.
- Have the current switched off.
- Never leave the machine until the contacted/damaged line has been switched off.
6.9 Operation below ground and in enclosed areas
If earthmoving machinery is used below ground or in enclosed areas, adequate
ventilation must
be provided and the valid regulations must be observed.
6.10
6.10.1
Stoppages
Prior to breaks or finishing work, the operator must move the earthmoving machine to
level ground
with an adequate bearing capacity and secure it from movement.
The operating devices must be set down or secured in such a way that no inadvertent
movement
is possible.
6.10.2
6.10.3
The operator must not leave the earthmoving machine unless the operating devices are
set down
or secured
Earthmoving machines must be parked only where they present no obstacle, e.g. to
public
highway or site traffic. If necessary they must be secured by warning devices such as
warning
triangles, warning cords, flashing or warning lamps.
Prior to leaving the operating stand, the operator must set all control devices to neutral
and apply
the brakes.
Before leaving the earthmoving machine, the operator must first switch off the driving
motors and
secure them against unauthorised starting.
Lifting-gear deployment
Lifting-gear deployment covers the lifting, transporting and lowering of loads by
means of a
slinging aid (cable, chain etc.), with the assistance of persons being required for
slinging and
releasing the load.
6.10.4
6.10.5
6.11
6.11.1
9707672_User manual_en