EasyManua.ls Logo

New Comfort SS-7000 - User Manual

New Comfort SS-7000
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
New Comfort
SS-7000
Commercial Air Purifier
OWNER’S MANUAL
Please read all of the information provided in this owner’s
manual before operating your new Commercial Air purifier.
Question and Answer IconNeed help?

Do you have a question about the New Comfort SS-7000 and is the answer not in the manual?

Summary

Specifications

Operating the Commercial Purifier

Timer Control Knob

Control for setting timed operation up to two hours.

Indicator Light

Light that illuminates when the unit is in operation.

High-low Switch

Switch to select ozone output between 12000 mg/hr (high) and 6000 mg/hr (low).

Operation

Operating Procedure

Steps for operating the commercial air purifier in unoccupied spaces, including timer settings and post-operation waiting periods.

Maintenance and Troubleshooting

Maintenance and Plate Replacement

Guidance on when and how to replace ozone plates, including safety warnings for maintenance tasks.

Fuse Replacement

Instructions on how to replace the unit's fuse, emphasizing the correct amperage and fuse holder procedure.

Troubleshooting Common Issues

Guidance on checking common issues like power connection, grounding, and fuse condition for unit problems.

Service and Warranty

Warranty Coverage and Claims

Details on the 3-Year Limited Factory Warranty, what it covers, and how to initiate a warranty claim.

Owners Records

Section for recording essential unit information like model number, serial number, and purchase date for future reference.

Overview

The New Comfort SS-7000 Commercial Air Purifier is a robust device designed for heavy-duty odor removal in unoccupied spaces. It features all stainless steel construction, ensuring durability for the toughest cleaning jobs.

Function Description:

The primary function of the SS-7000 is to eliminate powerful odors using ozone generation and UV light. It is intended for commercial use in areas up to 3500 square feet per treatment. The unit operates with a timer, allowing for a maximum run duration of 2 hours, after which it automatically shuts off. A 40-minute waiting period is recommended before re-entering the treated area to allow for proper ventilation.

Important Technical Specifications:

  • Model: SS-7000
  • Rated Voltage: USA/Japan AC 100-120V/50-60Hz
  • Power Consumption: 100W
  • Ceramic Plate Size (2 plates): 90X50MM
  • Air Volume: Max 100 CFM (2.8 M³/min)
  • Active Oxygen (Ozone) Output:
    • Low Mode: 6000 mg/hr
    • High Mode: 12000 mg/hr
  • Sound Level: 45 Db.
  • Product Size (mm): W6xH9xD13 IN
  • Weight: 6.4 lbs
  • Fuse: 1 amp, 0.79 inch in length (spare fuse included)
  • Warranty: 3-Year Limited Factory Warranty (covers the complete unit except for filters or Ozone Plates)

Usage Features:

  • Hi/Low Mode: Users can select between 12,000 mg/hr (High) or 6,000 mg/hr (Low) ozone output, depending on the size or type of the job.
  • Timer Control Knob: Allows setting the operation time up to two hours. The unit will automatically shut off once the timer expires.
  • Indicator Light: Illuminates when the unit is in operation, providing a visual cue that the device is running.
  • Powerful Fan: Facilitates effective air purification in spaces up to 3500 square feet.
  • UV Bulb: Cleans the air as the air purifier runs, adding an additional layer of air treatment.
  • Operation Procedure:
    1. Close off the desired area to be treated.
    2. Remove all occupants and pets from the area.
    3. Position the unit as close as possible to the odor source.
    4. In environments with individual heating and cooling systems (e.g., motels), turn the fan on and set it to re-circulate.
    5. Set the timer to the desired duration and leave the room.
    6. Allow 40 minutes for ventilation before re-entering the treated space.

Maintenance Features:

  • Ozone Plate Replacement: The ozone plates should be replaced when the unit no longer produces enough ozone, typically after approximately 5000 hours of operation.
    • Replacement Steps:
      1. Turn off the unit and unplug it from the outlet.
      2. Use a screwdriver to unfasten the cover screw and remove the cover.
      3. Pull the ceramic plate out of the ozone generator module.
      4. Install the new ceramic plate carefully, as shown in the manual's diagram.
  • Fuse Replacement: If the unit is not powering on, check the fuse.
    • Replacement Steps:
      1. Ensure the unit is unplugged.
      2. Pull out the plastic fuse holder.
      3. Remove the old fuse and insert a new 1 amp (0.79 inch) replacement fuse.
  • Cleaning: Failure to properly clean (every 6 months), inspect, maintain, and/or replace defective ozone plates may result in a fire hazard.

Safety Warnings:

  • Unoccupied Spaces Only: The device should only be used in unoccupied spaces due to the potential for excessive ozone concentrations to cause mucous membrane or respiratory irritation.
  • Not a Medical Device: This air unit is not a medical device. Do not stop or alter any medical therapy programs or medications without the advice of a physician.
  • Electrical Shock Risk: Do not remove the cover. There are no user-serviceable parts inside. Refer servicing to qualified service personnel. The "bolt of lightning" symbol indicates un-insulated material that may cause electrical shock.
  • Power Connection: Never plug the unit into a power strip; always plug it into a wall outlet.
  • Overheating Risk: Failure to clean and maintain ozone parts, or using the 'HOLD' setting longer than 2 hours per treatment, may result in overheating and could lead to a fire hazard.
  • Grounding: Ensure the Commercial Air Purifier is properly grounded to avoid potential shock.

New Comfort SS-7000 Specifications

General IconGeneral
BrandNew Comfort
ModelSS-7000
CategoryAir Cleaner
LanguageEnglish

Related product manuals