EasyManua.ls Logo

Next Victor NM-II 3.2KW 24V PF1 - LCD Setting and Configuration; Setting Voltage Points for Mode Switching

Next Victor NM-II 3.2KW 24V PF1
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
06
Auto restart when
overload occurs
Restart disable
(default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable
(default)
Restart enable
09
Output frequency
50Hz (default)
60Hz
11
Maximum utility
charging current
Note: If setting value in
program 02 is smaller
than that in program in
11, the inverter will
apply charging current
from program 02 for
utility charger.
Available options in 1KVA/2KVA model:
10A
20A (default)
Available options in 3KVA model:
15A
25A (default)
Available options in 3KW/
5KW
model:
2A
10A
20A
30A (default)
40A
50A
60A
12
Setting voltage point
back to utility source
when selecting SBU
priority or Solar first
in program 01.
Available options in 1KVA model:
11.0V
11.3V
11.5V (default)
11.8V
12.0V
12.3V
12.5V
12.8V
16