For installation in the UK and in smoke control areas
Contura 210, 210G, 5 kW woodburning stoves has been recom-
mended as suitable for use in smoke control areas. This when bur-
ning wood logs and operated in accordance with these instructions
and when fitted with a permanent stop to prevent closure of the
air control unit beyond 31% open position.
Note: When refuling - open the air control fully for 3-5 minutes
before closing down to the minimum air setting.
Mandatory for smoke control areas
The permanent stop must be installed if the appliance is to be
used in a smoke control area, this stop must not be removed in
smoke control areas, otherwise an offence will be committed if
the appliance is used without the permanent stop in place.