In particular we suggest to check the following points:
The goods quantity, type and design must fit what was stated in the order and listed in the transport bill
Make sure that there are not damaged or missing parts
Verify if the housing or the flange have dents
Check if some parts are not correctly fixed
The wheel must rotate easily, without touching other parts; make sure that the wheel is still balanced and fixed
correctly on the shaft
Verify the correct tightening of the screws
Make sure that the inner ring of the bearings is locked on the shaft
Check if shafts and frames have been bent during transport
Couplings between the shafts must be aligned
Atex fans must be accompanied by the following documents: “ Maintenance and Installation Manual”, “Atex
Certificate” and rating plate fixed on the housing
Note:
for any other information, please refer always to the relevant drawing, catalogue or contact our Technical
Department.
2.1. DATA ON THE RATING PLATE
MOD:
product description
COD:
Nicotra code
SERIAL:
serial number
COD. CLI:
customer code (optional)
WATT MAX:
max admissible power
RPM MAX:
max admissible speed
MAX BEARING LOAD:
max admissible radial load on bearing
Prod. Date:
production date
Instr. Code:
“Maintenance and Installation Manual” code
II 2 G:
Atex Group II, Cat.1, Gas (only Atex version)
c
type of protection against ignition risk (only Atex version)
T5:
max surface temperature class (only Atex version)