Troubleshooting
6-44 Manual # 42-02-7223 C1
Description: The auxiliary front photo-eye device (required for Peele doors for PHE integrity tests) has been
continuously activated for a user-defined time and is now bypassed in accordance to the user-defined set-
tings (Configuration > Car Operation > Doors > Door Device > Photo Eye).
Car Reaction: The auxiliary front photo eye device is rendered inoperative.
Tro ubleshooting:
1. To restore the operation of the photo eye device, check the corresponding input.
2. The operation of the photo eye device can also be restored by changing the Photo Eye Bypass option to
NO on iView.
3. Related Inputs: PHE2 Front - Normally low.
Front Photo Eye Failure, FRONT PHOTO EYE FAIL
Description: This event is logged when the photo eye is continuously activated for a predetermined time (4
seconds) while the front doors are fully closed.
Car Reaction: The front photo eye is rendered inoperative.
Tro ubleshooting:
1. Check for abnormal blockage or failure of the front optical device.
2. Related inputs: FrontPhotoEye: Normally low
Front Photo Eye Test Fail, FRONT PHOTO TEST FAIL
Description: The front photo eye devices integrity test (required under section 2.13.3.4.9 of the A17.1a-
2008/CSA B44a-08 elevator safety code) has failed. Indicating that one or both the main and auxiliary front
photo eye devices are not functioning properly and unable to detect an object.
Car Reaction: Car remains in service. Front doors are prevented from closing. The front photo eye devices
integrity test is repeated until it is determined that both the main and auxiliary front photo eye devices are
able to detect an object.
Tro ubleshooting:
1. Check that both the main auxiliary front photo eye devices are functioning properly and able to detect an
object.
2. Related Inputs: Front photo eye and PHE2 Front – Both Normally low
Front Photo Eye 2 Failure, FRONT PHOTO EYE 2 FAIL
Description: The auxiliary front photo eye device (required for Peele doors for PHE integrity tests) was con-
tinuously activated for a predetermined time (four seconds) while the front doors are fully closed.
Car Reaction: The auxiliary front photo eye is rendered inoperative.
Tro ubleshooting:
1. Check for abnormal blockage or failure of the auxiliary front optical device.
2. Related Inputs: PHE2 Front - Normally low
Front Photo Eye 2 Test Failure, FRONT PHOTO EYE 2 TEST FAIL
Description: This event is logged when the Front Photo Eye 2 input is ON while the front doors are fully
closed.
Troubleshooting: Check for abnormal blockage or failure of the front optical device. Related inputs: Front
Photo Eye 2
Front Safe Edge Bypassed, FRONT SAFE EDGE BYP
Description: The front door safe edge has been continuously activated for a user-defined time and is now
bypassed according to the user-defined setting. (iView Controller > Configuration > Car Operation > Doors)
Car Reaction: The front safe edge is rendered inoperative.
Tro ubleshooting:
1. Check the state of the front safe edge input.
2. Related inputs: SafeEdgeFront: Normally low
Table 6.3 iControl Messages