iControl Circuit Board Quick References
Manual # 42-02-7223 C1 6-97
6
iControl DC
ICE-FML Field Module Logic Board
iField Modules are used to supply power to the brake on iControl AC and DC systems and to the
motor field on iControl with DC drive. The iField Modules used for both purposes are the same,
with the exception of the wiring to terminal J7 on the ICE-FMP, Field Module Power Board.
ICE-FM Field Module Board
iField-Module-L is used to supply power to the brake on iControl AC and DC systems.
IFIELD-MODULE Specifications
Inputs: 70 VAC min, 300 VAC max, 1 Phase, 50/60Hz, 42 AMPS Maximum
Outputs: 0 VDC minimum, 265 VDC maximum, 45 AMPS Maximum
OVER-CURRENT PROTECTION REQUIRED ON INPUT
- For loads up to 30A - use Bussman type FNQ or LittleFuse type FLQ
- For loads over 30A - use Ferraz Shawmut type A50QS80-4 or LittleFuse type L50S80
IFIELD-MODULE-L Specifications
Inputs: 70 VAC Min, 300 VAC Max, 1 Phase, 50/60Hz, 8 AMPS Maximum Continuous
Outputs: 0 VDC Minimum, 300 VDC Maximum, 6 AMPS Maximum Continuous
OVER-CURRENT PROTECTION REQUIRED ON INPUT
- Replace with 5x10 mm 6.3A 500v SL0-BL0
- LittleFuse 047706.3 or equivalent