Your #PDC4000 Portable Air Duct Cleaning System has been thoroughly tested and inspected at the
factory and is fully assembled and ready for use. However, prior to plugging the unit in, inspect it for
any damage that may have incurred during shipping.
ELECTRICAL RATING:
115V 10 Amps 60 HZ - Each Motor
Use minimum of 12-3 gauge extension cords.
Each motor cord requires a separate 15 amp or 20 amp circuit.
FILTER AND SET-UP PROCEDURES
1) Turn off and unplug unit.
2) Remove the door w/12” flange by loosening the 4 – twist lock latches
(See Photo #1).
3) Place the HEPA filter in the HEPA filter cabinet, make sure the air
flow arrows on filter
are pointing towards the blower assembly. Use the 4 bolts to secure
the HEPA filter.
4) Connect the cube filter spacer frame to the 4 HEPA hold down bolts
and secure with the 4 – 5/16 nuts (See photo 3)
5) Place the Merv 11 Cube Filter inside the filter holding frame of the
door. (See photo 4)
6) Place door on the HEPA filter cabinet and secure by tightening the
latches. (See photo 5)
7) Connect the HEPA filter cabinet to the blower cabinet and secure
them together using the 4 latches.
8) Connect the 12” clear hose to the 12” intake flange on the door of the
prefilter cabinet and using the hose clamp provided, secure tightly.
9) Mount the duct intake collar at your access point.
10) Connect the 12” clear hose to the duct intake connector using the
hose clamp provided.
11) Unit is ready for operation.