9 Main technical Data
Type
C 100.6 C 105.6 C 110.4 C 120.6
Electric specifications
Rated voltage V 220-240 120 220-240 220-240 220-240 120
Rated frequency Hz 50/60 60 50/60 50/60 50/60 60
Rated power consumption kW 1.3 1.4 1.4 1.4
Current A 5.7 11 6.1 6.1 6.1 12
Protection class
Class I/
Class II
Class II Class II Class II Class II
Protection degree IP xx IPX5 IPX5 IPX5 IPX5
Hydraulic specifications
Rated pressure MPa/bar 7/70 7/70 7.5/75 8/80 8.5/85 8/80
Max. pressure MPa/bar 10/100 9/90 10.5/105 10/110 12/120 10/100
Rated water flow l/min/l/h 5.3/320 5.2/310 5.2/310 5.2/310 5.3/320
Max. water flow l/min/l/h 7.3/440 7.3/440 7.3/440 7.3/440
Max. water inlet pressure Mpa/bar 1/10 1/10 1/10 1/10
Max. water inlet temperature °C 40 40 40 40
Max. water inlet temp. suction mode °C 20 20 20 20
Weight kg 5.1 (6.1)* 5.5 6.1(6.5)** 6.7
Hand-arm vibration according to
ISO 5349-1: Standard nozzle
m/s
2
< 2.5 ±1 < 2.5 ±1 < 2.5 ±1 < 2.5 ±1
Sound pressure level L
pA
in accord-
ance with ISO 3744
dB(A) 74 ±3 74 ±3 74 ±3 74 ±3
Guaranteed sound power level L
WA
in accordance with 2000/14/EC
dB(A) 90 90 90 90
We reserve the right to make alterations.
* C 100.6-6, ** C 110.4 X-TRA