POSEIDON 3
12 Original Operating Instructions
Technical Data
POSEIDON 3-24 /XT 3-26 /XT
3-30 /XT 3-40 /XT
Possible voltage, V/ph/Frez. V/ph/Hz 240/1/50 (AU) 230/1/50 (GB, S) "230/1/50
220/1/60 (EXP, KR)
110/1/50 (GB)"
"230-400/3/50 (NO)
220-440/3/60 (EXP)
400/3/50
415/3/50 (SG)"
Fuse
A 10 13 "16
15 (EXP, KR)
32 (GB)"
16
Power rating kW 2,3 2,6 "3,4
3,3 (EXP, KR)
3,0 (GB)"
4,2
Working pressure p
IEC
bar (MPa) 95/9,5 "140/15 (GB)
130/13 (S)"
"145/14,5
135/13,5 (EXP, KR)
(2000 psi)
130/13,0 (GB)"
170/17
Water flow Q
IEC
l/h 600 "570 (GB)
600 (S)"
"600
560 (EXP, KR)
(2.4gal)"
750
Max. water pressure p
max
bar (MPa) 135/13,5 160/16 "160/16
150/15 (EXP, KR)
(2175psi)"
200/20
Water flow Q
max
l/h 660 660 "660
(3gal)"
825
Max. Water inlet temp.
inlet-pressure operation
*
C°(F°) "60(140)
max. 1 hour"
"60(140)
max. 1 hour"
"60(140)
max. 1 hour"
"60(140)
max. 1 hour"
Max. water inlet pressure bar (MPa) 10 (1) 10 (1) 10 (1) 10 (1)
Max. dry suction height m 1 1 1 1
Dimensions, l x w x h mm
Weight of cleaner kg 35 35/37 35/37 36/38
Sound pressure level L
PA
at a distance of 1 m dB(A) 78,7 78,7 78,7 82,3
Guarantied sound power level L
WA
dB(A) 93 93 93 97
Vibration ISO 5349 m/s² <1,5; ±1 <1,5; ±1 <1,5; ±1 <1,5; ±1
Recoil forces, lance1 / lance 2 N 23,5 27,5 "28,4
25,5(EXP, KR)"
39
Specifi cations and details are subject to change without prior notice
*For periods of max. 1 hour a water temperature of max. 60°C is allowed