EasyManua.ls Logo

Ningbo VSETT 10+ - Programming Codes (P-Codes)

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P01Backlight brightness:The 1 level is the darkestLevel 3 brightestDefault: 3
P02Mileage: unit,0KM1MILEDefault: KM
P03: Voltage level: 24V36V48V52V60V.
P04: Dormancy time:0 means no dormancy;Other numbers are dormant time.The range is 1-60 minute.Default:5
P05: Reserve
P06: Wheel diameter: The unit is inch. The accuracy is 0.1; Default:10.0
P07: Speed measuring magnetic steel number.The range is 0-255. Default:28
P08: Rate-limiting: The range is 0-100km/h.Default: 100
P09: Zero startno zero start setting0 means zero start.1means no Zero start.Default: 0
P10:Reserve
P11: EABS switch choose.The range is 1-5.0 means closing.1 means weakest.2 means strongest.
P12: Soft and hard start strength.The range is 1-5. The softest is 1.The hardest is5.Default: 3
P13: Reserve
P14: Reserve
P15: Controller under-voltage
P16: ODO Zero setting: keep pressing + for 5 seconds,ODO will zero clearing.
P17: When it shows 0,it can not use cruise.When it shows 1,it can use cruise.Default:0
P18: Bind and unbind NFC CARDS.Long press "+" to build the binding, long press "-" to build the unbinding
P19: Reserve
P20: Communication protocol is defaults 4.It can not change.
Display P-Codes (Programming codes)
To access this menu, long-press and . Use button to scroll through P-codes, and to change parameters.
Vsett display operation and programming
Vsett display operation and programming

Related product manuals