User Instruction
For special fitting demand, N95 respirator WB-N-300-FILTER, TC-84A-8475.
Warning
Before occupational use of this respirator, a written respiratory protection program must be implemented meeting all the local
government requirements. In the United States, employers must comply with OSHA 29 CFR 1910.134 which includes medical
evaluation, training, and fit testing.
This respirator helps protect against certain particles. Misuse may result in sickness or death. For proper use, see supervisor,
User Instructions, or call 001 4697671124.
Company Name: WellBefore
Address: 11528 Harry Hines Blvd. Suite A102 Dallas TX USA 75229
Tel: 001 4697671124
USE LIMITATIONS:
1. Do NOT use the respirator or enter or stay in a contaminated area under the following circumstances:
• Atmosphere contains less than 19.5% oxygen.
• Atmosphere contains oil aerosols if using N protection class respirator.
• For protection against gases or vapors.
• Contaminants or their concentrations are unknown or immediately dangerous to life or health.
Concentrations or contaminants exceed maximum use concentrations in applicable OSHA standards or applicable government regulations or
10 times the PEL (Permissible Exposure Limit), whichever is lower.
• For sandblasting, paint-spray operations, asbestos.
2. Do NOT modify or misuse the respirator.
3. Do NOT use the respirator with beards or other facial hair that interferes with direct contact between the face and the edge of the respirator,
or any other conditions that may prevent a good face-seal.
WARNING:
This respirator helps protect against certain contaminants. It may not eliminate the risk of contracting disease or infection. Misuse may result in
sickness or death. Materials which may come into contact with the wearer’s skin could cause allergic reactions to susceptible individuals.
FOR MORE INFORMATION or assistance please contact with Manufacturer.
FITTING INSTRUCTIONS:
Follow these instructions each time respirator is worn.
1. Hold the respirator in one hand with the nosepiece at your fingertips, allowing the headbands to hang below your
hand. 2. Press the respirator against your face with the nosepiece on the bridge of your nose.
3. Place the top band high on the back of your head. Move the bottom band over your head and position it below your
ears. 4. Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the nose area to the
shape of your nose by pushing inward while moving your fingertips down both sides of the nosepiece.
Warning: Pinching the nosepiece using one hand may result in improper fit and less effective respirator performance.
Use two hands.
5. Fit-check the face-seal as follows:
• Place both hands over the respirator without disturbing its position.
•Inhale sharply, a negative pressure should be felt inside the respirator.
• If you detect air-leaks, readjust the nosepiece and/or head straps position.
WARNING: If you cannot achieve satisfactory fit, do NOT enter the contaminated area. See your Supervisor.
USE INSTRUCTIONS:
1. Failure to follow all instructions and limitations concerning the use of the respirator and/or failure to wear the
respirator for the whole duration of exposure to contaminants can seriously reduce the performance characteristics of
the respirator and lead to illness, injury or death.
2. Before use, the wearer must first be trained by the employer in the correct use of the respirator in accordance with
applicable safety and health standards.
3. OSHA standards including 29CFR1910.134 (e) (5) and CSA standard Z94.4-93 require that the wearer be fit-tested.
4. Discard the respirator and replace with a new one if:
• Excessive clogging of the respirator causes breathing difficulty.
• The respirator becomes damaged.
5. Leave the contaminated area if dizziness, irritation or other distress occurs.
6. This respirator has been tested and small punctures within ultrasonic welding areas are normal and do not interfere
with the respirator compliance with Part 84 approval requirements: (A) filtering facepieces are to be inspected prior
to each use to assure there are no holes in a breathing zone other than the punctures within ultrasonic welding areas
and no damage has occurred, and (B) enlarged holes resulting from ripped or torn filter material within ultrasonic
welding areas punctures are considered damage.
S-Special Instruction Section:
The model
WB-N-300-FILTER
filtering facepiece respirator has been manufactured by approval holder Suzhou Sanical for private label WellBefore
under TC-84A-8475.
WB-N-300-FILTERUI A/0 Date: Apr 25, 2021
Question and Answer IconNeed help?

Do you have a question about the NIOSH N95 and is the answer not in the manual?

NIOSH N95 Specifications

General IconGeneral
NIOSH ApprovalYes
Filter ClassN95
Filter Efficiency≥95%
ApprovalNIOSH
TypeParticulate Respirator
Oil ResistanceNot resistant to oil
BreathabilitySpecific requirements defined by NIOSH standards
Intended UseProtection against non-oil-based particulate aerosols

Summary

General Respirator Warnings and Limitations

Respiratory Protection Program Requirement

Employers must implement a written respiratory protection program with medical evaluation, training, and fit testing.

Respirator Misuse Warning

Misuse of the respirator can result in sickness or death; consult supervisor or user instructions for proper use.

Use Limitations

Details specific circumstances where the respirator should not be used, including oxygen levels and contaminant types.

Respirator Fitting and Use Instructions

Fitting Instructions

Step-by-step guide for properly fitting the respirator to ensure a good seal, emphasizing the use of two hands.

Fit-Check Procedure

Instructions on how to perform a fit-check by inhaling sharply to detect negative pressure or air-leaks.

Use Instructions

Guidance on following all instructions, wearing the respirator for the entire exposure duration, and discarding if damaged.

NIOSH Approval Information

Approval Label Details

Shows the NIOSH approval label with TC number, protection type (N95), respirator model, and associated cautions.

Cautions and Limitations Summary

Lists specific cautions and limitations (A, B, C, J, M, N, O, P, S) related to the respirator's use and approval.