AUTOMATIC SOFTENERS SERIES:
AM/T - AM/RT
AM/V - AM/RV
AM/METER - AM/R METER
INSTRUCTIONS MANUAL
WARNING!
The equipment must be used only for the utilization for which they have been
designed, as shown in the technical documentation.
Read carefully this leaflet until the end before starting any operation.
Proceed strictly according to all directions included in this manual.
Automatic softeners series AM are designed to treat raw water supplied from
municipalities or from well.
ANY OTHER APPLICATIONS OF THE EQUIPMENT DIFFERENT THAN THE MENTIONED
ONES IS MADE UNDER THE ONLY RESPONSIBILITY OF THE USER.
For any assistance concerning the installations, maintenance or utilization of the equipment
apply the NOBEL Service Center closest to you or directly:
NOBEL S.r.l.
e-mail: nobel@nobelitaly.it
tel. +39 02 2827968 fax +39 02 2610839

Questions and Answers

  • T
    timothy84Aug 18, 2025
    What to do if Nobel Water Dispenser doesn't draw brine during regeneration?
    • C
      Connie Griffin MDAug 18, 2025
      If your Nobel Water Dispenser isn't drawing brine during regeneration, several issues could be the cause. The drain line might be clogged or too small, requiring a rebuild. Low water pressure could be the culprit, so increase it. Check for air being drawn along the brine line by inspecting connections and tubing. The injector or its filter may be dirty, so clean them. Lastly, the brine float valve could be blocked or damaged; in that case, clean or replace it.
  • A
    Amy KlineAug 21, 2025
    Why is my Nobel AM's brine tank overflowing?
    • K
      Kyle WalkerAug 21, 2025
      If the brine tank of your Nobel Water Dispenser is overflowing, it could be due to two reasons. Firstly, the drain line of the softener might be joined with the overflow line of the brine tank; in that case, connect them separately to the floor drain. Secondly, the brine float valve might be blocked or damaged; you should clean or replace it.
  • C
    Christopher MilesAug 23, 2025
    Why does my Nobel AM Water Dispenser feed salted water after regeneration?
    • A
      Aaron LarsenAug 23, 2025
      If your Nobel Water Dispenser feeds salted water after regeneration, it could be due to a water failure during regeneration. In this case, allow the water to flow until it is not salted any more. Alternatively, the fast rinse time might be too short; adjust it to a longer duration.
  • S
    Sara RichAug 26, 2025
    What to do if Nobel AM Water Dispenser leaks water to drain during service?
    • R
      Ryan YoungAug 26, 2025
      If your Nobel Water Dispenser leaks water to the drain during service, the internal pistons of the control valve could be blocked; try cleaning or replacing them. Alternatively, the O-rings or the pistons themselves might be spoiled, or the pilot pistons spoiled or broken, requiring replacement.
  • C
    Corey WhiteAug 27, 2025
    Why is my Nobel Water Dispenser not feeding treated water?
    • M
      mgutierrezAug 28, 2025
      If your Nobel Water Dispenser is not feeding treated water, it could be due to several reasons: regeneration might not be running, brine might not be drawn, a water failure might have occurred during regeneration (run regeneration again), or the resins might be spoiled (replace resins).
  • S
    steven39Aug 30, 2025
    What to do if Nobel AM Water Dispenser regeneration never ends?
    • J
      Joseph StewartAug 30, 2025
      If regeneration never ends on your Nobel Water Dispenser, the electronic programmer may have received electromagnetic interference. Try making a short-circuit on the battery of the programmer and re-enter all programming data. Another possible cause is a defected microswitch of the programmer, which would need replacement.
  • C
    carpenterdanielSep 1, 2025
    What to do if the buttons of the electronic programmer of Nobel AM Water Dispenser are on block?
    • Y
      Yolanda CannonSep 1, 2025
      If the buttons of the electronic programmer on your Nobel Water Dispenser are blocked, it could be because a regeneration is running; wait until it is completed. Another reason might be electromagnetic interference; in that case, make a short-circuit on the battery of the programmer and re-enter all programming data. It is also possible that the programmer itself is defected, and needs to be replaced.
  • J
    Julia BennettSep 3, 2025
    How to fix a Nobel AM when the electronic programmer does not switch on?
    • C
      craig66Sep 4, 2025
      If the electronic programmer on your Nobel Water Dispenser does not switch on, first check if the electrical power is disconnected and connect it. If power is connected, the electrical feeder of the programmer may be defected and require replacement. As a last resort, the programmer itself might be defected, requiring replacement.
  • D
    david94Sep 6, 2025
    Why Nobel AM Water Dispenser regeneration does not run?
    • M
      markriveraSep 6, 2025
      If regeneration does not run on your Nobel Water Dispenser, it could be due to disconnected electrical power; connect the power. Another cause might be an incorrectly adjusted programmer; adjust it correctly. The programmer itself could also be defected, requiring replacement.
  • J
    Joseph MccallSep 8, 2025
    Why Nobel AM does not feed water?
    • J
      John DaviesSep 8, 2025
      If your Nobel Water Dispenser does not feed water, it may be because the pistons are blocked during regeneration; clean or replace the pistons.

Summary

Instructions Manual

Safety Precautions

Technical Specifications

Model-Specific Data

Detailed specifications for various AM models.

Installation Procedures

Unit Placement and Setup

Steps for placing and initial setup of the unit.

Connections and Wiring

Hydraulic Connections

Procedures for connecting water lines to the unit.

Electrical Wiring

Procedures for connecting electrical wiring.

Regeneration Cycles

End Cycle Definitions

Explanation of automatic regeneration triggers and types.

Regeneration Process Details

Unit Starting Procedure

Service and Maintenance

Troubleshooting Guide

Installation Diagrams

Declaration of Conformity

Nobel AM Series Specifications

General IconGeneral
BrandNobel
ModelAM Series
CategoryWater Dispenser
LanguageEnglish