EasyManua.ls Logo

Nobile BT - Page 2

Nobile BT
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Montage
-
/
Betriebsanleitung
Mounting-/Operation Instruction
Präsenzmelder
BT
-
SI
Presence detector BT for LED High Bay F400-SI
Seite 2 von 2
Technische und gestalterische Änderungen im Zuge stetiger Produktentwicklungen vorbehalten.
Technical and design changes due to product developments are subject to change without prior notice.
nobilé AG – Wächtersbacher Str. 78 - 60386 Frankfurt/M. Germany - www.nobile.de rev. 0.1 – 03.05.2022
EN
Congratulations on your purchase of this nobilé-product!
You have decided on a high-quality product which is manufactured with the utmost care and subject to several quality controls. Safe use of the
product is only guaranteed if each instruction is followed accordingly. In case of damage caused by non-observance of these instructions the warranty
expires. The installation and electrical connection must be done by an authorized expert (e.g. electrician) in compliance with existing standards and
local code. Prior to any installation or maintenance work, mains must be disconnected. Before putting in operation, make sure any component of the
entire installation does not bear a risk of life. According to common practice, please perform a standard function test, before installing. To make
maintenance work possible, the lighting system should be accessible after installation (auditable).
Mounting:
Warning!
1. The sensor has a warm up time of 15 seconds after the switching on the lamp. At this time the lamp will be at full bright.
2. Default factory setting: Sensitivity-100%, Hold-time-5min., Daylight sensor - Off, Stand-by dim level - 30%, Stand-by time - 60 min.
3. The lamp will switch On and Off to confirm a change made through the remote control.
Motion Sensor
with sufficient natural light, the
lamp will not switch-on even a
presence is detected
with insufficient natural light, the
sensor will switch the lamp ON
when a presence is detected
After the set Hold-time, the lamp
will dim down to the set Stand-by
level when no presence detected
The lamp will switches off
automatically after the Stand-by
time elapses
Daylight Sensor
with insufficient natural light, the
sensor will switch the lamp ON
when a presence is detected
with sufficient natural light, the
lamp will not switch-on even a
presence is detected
Technical Specifica
tion
Power Supply 12V – 24V DC
Transmission protocol Bluetooth Mesh
Operation Frequency 2,40 GHz
Transmission Power 100 dB
Detection Range max. 8m radius
Installation height max. 12m
Ambient Temperature Ta -20 ~ 60°C
free to download
nobile Smartmatic 2.0 APP
on Google Play or Apple APP Store