MOTIONSENSOR SECURITY LIGHT
IMPORTANT: Please read this manual carefully before assembly and save it for reference.
Wiring the unit incorrectly may damage the electronic components inside this control module and can cause a fire hazard.
Doing so will void all warranty claims.
1. Mounting strip
2. Outlet box (not provided)
3.
4.
Black live wire
5.
White neutral wire
6.
Gasket
Sensor
1
2
3
4
5
6
Know Your Motion-sensor Security Light
ELECTRICAL INSTALLATION:
1)
Pla
ce the wall switch
to the”OFF” positio
n.
2) Depending on which type of fuse
box you have in your home:
Place either the main (Master)
switch to the “OFF” position,
cutting o power to your entire
home, OR turn o the individual
switch that provides power
to where the fixture will be installed.
OR
3) Place either the main (Master)
switch to the “OFF” position,
cutting o power to the entire
home, OR unscrew the fuse
that provides power to where
the fixture will be installed.
NOTE: Shutting o a wall switch that controls the light is not
sucient to prevent electrical shock.
WARNING: This product must be installed in accordance
with the applicable installation code by a person familiar
with the construction and operation of the product and the
hazards involved.
model no. 052-7801-8 & 052-7802-6 | contact us: 1-866-827-4985
For outdoor use
Retain carton for storage purposes
Instruction Manual
Detection method: Passive infrared sensor
Sensor range: 10–40' (3–12 m), 180º spread
Power source: 120 V AC 60 Hz
Load rating: 300 W max. (2 x 150 W)
Power consumption: 4 W max. for the sensor unit only
SpecificationsInstallation Guide
Question and Answer IconNeed help?

Do you have a question about the NOMA 052-7801-8 and is the answer not in the manual?

NOMA 052-7801-8 Specifications

General IconGeneral
BrandNOMA
Model052-7801-8
CategorySecurity Sensors
LanguageEnglish

Summary

Specifications

Detection Method

Passive infrared sensor.

Sensor Range

10-40' (3-12 m), 180º spread.

Power Source

120 V AC 60 Hz.

Load Rating

300 W max. (2 x 150 W).

Power Consumption

4 W max. for the sensor unit only.

Electrical Installation

Power Disconnection Safety

Ensure power is off at wall switch and fuse box before starting installation.

Getting Started

Optimal Mounting and Placement

Mount unit 8' 5" (2.6m) high, avoid heat sources and direct sun.

Sensor and Bulb Positioning

Point sensor down, keep bulb above sensor to avoid false triggers.

Weatherproofing

Seal fixture base with weatherproof silicone caulk.

Wiring Connections

Connect white wire to white, black wire to black. No ground wire required.

Control Module Operation

Sensitivity Adjustment (SENS)

Adjust sensitivity via push-button; LED indicates level (red=high, green=low, orange=medium).

Light Duration Adjustment (TIME)

Adjust light duration via push-button; LED indicates time (red=3 min, green=30s, orange=1 min).

Manual Override Function

Control light manually by cycling wall switch: on-off-on for manual, off for auto.

Test Mode Activation

Remove silver sticker to enable sensor function at night after setting.