INTRODUCTION
Torque Tool Tester (TTT) is a bench top measuring instrument which has three transducer inputs. It has 10
measurement modes, 13 units of torque (with additional USER units feature), 12 pairs of limits and text
displayed in 11 languages.
Part numbers covered by this manual: 43228 TTT.
Parts Included
Description
Part Number
Quantity
Torque Tool Tester Instrument
43228
1
a.c. power adapter
38877
1
Power cord
-
1
Operators manual
34308
1
Calibration Certificate
-
1
Quick reference card(s)
34315
-
Serial data lead
39264
1
TTT carry case
26716
1
Accessories
Description
Part Number
TTT to 10 way lead, for Norbar Rotary Transducers
60216.200
TTT to 6 way lead, for Norbar Static & Annular Transducers
60217.200
TTT to no connector (for non-Norbar transducers)
60223.200
Serial Data Lead Kit
60248
Extensive range of torque transducers
Contact Norbar
FEATURES AND FUNCTIONS
The pictorial panel allows easy mode selection for the 6 modes of operation.
Additionally the 4 Peak modes can be configured for automatic reset.
3 transducer connectors.
Automatically recognises any ‘SMART’ Norbar transducer.
Can also work with most mV/V transducers from Norbar or other manufacturers.
13 Torque units, plus the ability to specify USER measurement units up to a maximum of 6 characters.
5 digit resolution for all Norbar transducers.
Operational from internal rechargeable battery or a.c. supply.
Fast battery charge in 3 hours 20 minutes.
There are 12 pairs of limits available.
Each limit has a target value and upper and lower tolerances.
The display shows LO / OK / HI with bright LED’s to signal AMBER / GREEN / RED for easy
confirmation. The limit status is also output on the ancillaries connector and serial port.
Pulse count feature in ‘Impulse Tool’ mode & ‘Clutch Tool’ mode.
User selectable frequency response for each mode of operation.
Password protection of all selectable features. The instrument can be issued to an operator with only
the required modes of operation and units of measurement enabled. This feature can virtually eliminate
operator induced errors.
Ancillaries connector with analogue output & GO/NO GO control for external equipment.
Serial Port for data output to a PC or printer.
Serial Port set up options include: sending time & date, limit status and continuous output.