Problem Solution
Backow of smoke into the room
when opening the stove door
the door may have opened too
abruptly, creating negative pressu-
re in the combustion chamber
slowly opening the door
closed, adjustable ue sha (if the
installation has such an option)
opening the sha
insucient air circulation in the
room where the stove is installed
Check the eciency of ventilation
and make sure there is enough air
in the room
atmospheric conditions
insucient dra
check the operation of the
installation chimney
Heating with low productivity or
phenomenon heater extinction
insucient wood in the stove
increase the amount of wood to the
required level
fuel humidity too high
use wood with a
humidity up to 20%
insucient dra check the eciency of ventilation
Low heating capacity with correct
combustion process in the stove
unsuitable, low-caloric wood was
used
switching to a more caloric type of
wood being burned
fuel humidity too high
use wood with a
humidity up to 20%
thin, ne pieces of wood are used
that burn quickly
use for smoking other thicker
clearance
Dirty glass, no self-burning glass
too slow combustion of wood
resulting in low combustion
chamber temperature
increase the amount of air in the
combustion chamber, use wood
with a moisture content of 20%
coniferous wood with high resin
content was used
changing wood type to dry
rewood
If the device does not work
correctly, it may be due to extreme
factors.
tall objects too close to the
chimney
increase the height of the
chimney or use a
'reman' or other type of hood
unsuitable atmospheric
conditions, e.g. wind or lack of
wind, low air pressure, high
humidity, fog, etc.
use a chimney pot, but if this does
not help, a chimney sweep should
be called in to determine the
source of the problem
MALFUNCTIONS AND SOLUTIONS DURING OPERATION
28