Instruction Sheet 46-75
Page 12
2300 Retrofit
/-
LAMP (P,‘N 939 665)
CIRCUIT BOARD
Figure 9 - Position of PM1 Light (Top View)
NOTE: The contacts are rated for 250 volts,
5 amperes.
10. Reconnect the plug of the two-part terminal block to its recep-
tacle at the bottom of the PM1 board.
NOTE: Make sure that the PM1 board is still
securely connected to the main circuit
board at all four pin locations. The pins con-
nect the PM1 board to the main board
electrically as well as phy:sically.
11. Return the main circuit board to an upright position and
secure it to the base of the applicator with the two screws
removed in a previous step.
12. Reconnect the white plugs to their receptacles along the top of
the main circuit board. Connect the plug labeled 1 and to the
connector labeled Jl on the circuit board, plug No. 2 to connec-
tor 52, and so forth, until all plugs are connected.
Issued l/89
ONORDSON CORPORATION 1968
All Rights Reserved
Pub. No. 108 428A