Procedure Diagram
11. ReplacingtheCopperHeatExchanger
(1) Remove12screwsholdingburner
toheatexchanger
(2) SeparateburnerfromCUHE
12. Removeheatexchangercomponents
andputonnewheatexchanger
(1) LeftSide:FreezePreventionHeater
(2) RightSide:HighLimitSwitch
(3) Thermalfuseandfastenersfrom
foursidesofheatexchanger

LEFTSIDE
BACK
RIGHTSIDE
FRONT
Page 9