Be sure to do
Prohibited
Prohibited
Avoid installation above gas ranges or stoves.
Avoid installation between the kitchen fan and stove.
If oily fumes or a large amount of steam are present in the
installation location, take measures to prevent the fumes
and steam from entering in the equipment.
Install in a location where the exhaust gas flow will not be
affected by fans or range hoods.
Take care that noise and exhaust gas will not affect neighbors.
Avoid installation on common walls as the unit will make
some operational noises while it is running.
Before installing, make sure that the exhaust flue termination
will have the proper clearances according to the National Fuel
Gas Code (ANSI Z223.1).
Installation must conform with local codes, or in the absence
of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA
54- latest edition and/or CSA B149.1, Natural Gas and Propane
Installation Code (NSCNGPIC).
State of California: The boiler must be braced, anchored or strapped to avoid moving during an earth-
quake. Contact local utilities for code requirements in your area or call: 1-866-766-7489 and request
instructions.