5
Avoid installation above gas ranges or stoves.
Avoid installation between the kitchen fan and stove. If oily
fumes or a large amount of steam are present in the installation
location, take measures to prevent the fumes and steam from
entering in the equipment.
Install in a location where the exhaust gas ow will not be
affected by fans or range hoods.
Take care that noise and exhaust gas will not affect neighbors.
Avoid installation on common walls as the unit will make some
operational noises while it is running.
Before installing, make sure that the exhaust ue termination will
have the proper clearances according to the National Fuel Gas
Code (ANSI Z223.1-latest edition) or the Natural Gas and Propane
Installation Code (CSA B149.1).
State of California: The Combi Boiler must be braced, anchored or strapped to avoid moving during an
earthquake. Contact local utilities for code requirements in your area or call: 1-866-766-7489 and
request instructions.
Be sure to do
Prohibited
Prohibited
CAUTION
For Venting Manufacturers Requirements, see website listed below:
Noritz N-Vent www.noritz.com
The Combi Boiler is designed for indoor installation only.
Never install it outdoors or in a bathroom, it may be damaged or a re may be caused.
Install the Combi Boiler in a location where it is free from obstacles and stagnant air.
Consult with the customer concerning the location of installation.
Do not install the Combi Boiler near staircases or emergency exits.
Install the Combi Boiler in an area that allows for the proper clearances to combustible and
non-combustible construction. Consult the rating plate on the appliance for proper clearances.
Do not install the Combi Boiler in a place where it may be threatened by falling objects, such as
under shelves.
• The Combi Boiler must be installed in a place where supply and exhaust pipes can be installed as
directed.
Do not install the Combi Boiler where the exhaust will blow on outer walls or material not resistant
to heat. Also consider the surrounding trees and animals.
The heat and moisture from the Combi Boiler may cause discoloration of walls and resinous materials,
or corrosion of aluminum materials.
Do not locate the vent termination directed towards a window or any other structure which has
glass or wired glass facing the termination.