1.5 Combustion Products
Appliances should be installed in places appropriate for the removal of fumes according
to installation specifications. Our appliances are classified as gas type A.
Such appliances must send fumes into appropriate air extractors connected to safe and
effective pipes that direct them outdoors.
! CAUTION !
Appliances must always be positioned below 200 mm ON THREE SIDES an air
extractor, which directs fumes outdoors.
Appliances with an overall thermal power exceeding 14 Kw must be installed below an
air extractor with a switch and pilot for the gas supply system.
Specifically, the supply circuit electric valve at the top
of the appliance must be switched-off.
Make sure there are set by installation standard UNI-CIG 8723,
point 4.3 ‘’Removal of combustion products’’.
Indicatively, the air extractor must guarantee aspiration power
equivalent to 35 m³ of air per hour for every Kw of thermal
power provided.
Pipes to collect fumes from the appliances and direct them to
a single air-extractor point can be provided at your request.
In this case, too, the appliance must be placed under an
air-extractor.