2.3 CONTROL OF THE OPERATION................................................................
Verify the stability of the appliance on the plan of support.
Check that there is a good influx of fresh air.
Check that there are no leaks or losses of gas.
Put in operation the appliance.
Check the stability of the flame of the main burden.
Check that non-combusted gases have an appropriate outlet.
2.4 INTERVENTIONS, REPAIRS AND REPLACEMENT(only for the
authorized technicians)......…………………………………………………….
Even if the appliance is used correctly, some problems may arise for various
reasons. The table that follows mentions some possible problems and some
suggestions to put them right.
CAUSION!!!!
Before performing any intervention of maintenance, reparation or simple
cleaning of the appliance it is necessary to close the gas supply gate valve
at the top of the appliance.
At the end of every intervention of reparation or maintenance to some
parts of the appliance relate to gas, make sure that there are no leaks or
looses.
FIGURE 8 - POSSIBLE PROBLEM
PROBLEM POSSIBLE CAUSES
Gas Smell Possible gas loss.
Check external pipes and connections.
Smell of non-burner gas
Check that the combustion is regular.
Check that the consumption of gas is not
excessive.
Check that there are not obstructions in the
encircled of the warm smokes.
Check that aspirant and area ventilation are
operating property.
‘Explosions ' in the burners Check the pressure of the gas.
The main burner is not ignited
Check that there is no leak in the gas supply or
any problem with the nozzle.
The components of the burner are well
positioned.