5
solenoids. Power must be supplied separately to the solenoids
by utilizing an appropriate relay. BLUE = Stage 1 Solenoid
Ground Output and RED = Stage 2 Solenoid Ground Output.
NOTE: These channels have a max current rating of 40 AMPS.
8. The 3-pin connector on the main controller is for an optional
nitrous pressure transducer input P/N 15661NOS. This kit
includes the pressure sensor transducer and cable and is sold
separately. Install the sensor at the bottle and plug into the
harness.
9. The 4-pin connector is for the handheld display. This is a
simple plug and play connection. If you are going to
permanently leave the handheld in the vehicle, you will need to
find a factory grommet in your firewall to pass the Display CAN
bus connect through and secure the excess wire away from
hazards. If no factory grommets can be utilized, we recommend
installing one purchased online or from your local auto parts
store.
HANDHELD
The main screen of the NOS Mini 2-Stage Progressive Nitrous
Controller displays: engine RPM, Bottle Pressure (bottle pressure
display can be turned on or off in the dash setup menu), Stage 1 &
Stage 2 activation RPM via colored bars (Blue = Stage 1, Yellow =
Stage 2), Stage 1 & Stage 2 ON/OFF display (ON is only displayed
when the solenoids are actively being trigged). By selecting the gear
icon at the top right corner, you will be directed to the main
menu screen. Here you can select from the menu items. Selecting
the will take you back to the home screen.