* Factory settings
Programming Overview
1x
3-9
30-
37
Exit
EnterMenu Item
GB
Exit menu
Deletingradiocodes (press for 5 sec.)
Programmingthelightbuttononthetransmitter
Programming the START button on the transmitter
Exit menu
Entering the control address
Activating the control elements for 10 secs.
Block control panel and external control elements
Block external control elements
Block control panel
Impulse transmitter Open-Close
Keyswitchfunction(J7)
Selection
4
3
2
1
0*
Entry
52
50
- -
Menu-
point
No.
6
- -
60
62
63
- -
Radio
5
Miscellaneous settings
Exit menu
Selection
Entry
Menu-
point
No.
4
Wipe impulse ELTACO
Hand transmitter on / off
5 minutes garage light
2 minutes garage light
Door open signal / loading lamp
Door closed signal
StatusrelayX5
5
4
3
2
1
0*
45
Extendeddoorsettings
Signal for automatic return
6
001-256
Plug-inmodule
off
0*
Actuation profiles, see plug-in module
1, 2, 3
53
Extensioncontrolunit
off
0*
Actuation profiles, see extension control
1, 2, 3
54
Input spring force
off
Springbreakagedetection
1 - 99
0*
47
Input cut-off force
off
Openingforcelimit
1 - 98
0*
48
4
2
Motorstartingtime
1
0*
49
5
6
3
Display spring balance (press 5 sec.)
Carry out weight measuring run with test weight99
14.15 25Min / 60%Gear motor
Gear motor 9.15, 9.20, 9,24 25Min / 60%
5.24 25Min / 35%Gear motor
Without limitation
Gear motor 9,24 WS 25Min / 20%
5.24 WS 25Min / 30%Gear motor
Gear motor 6.65 DU 10Min / 35%
Switch to dead man's Close
5
Doorsettingforsmoke-heatexhaustposition
55
Miscellaneous settings
3 seconds advance warning before close move
Red traffic light without early warning phase
3
2
Door open signal
Door closed signal
StatusrelayX6
1
0*
46
3 seconds advance warning before open andclose move
4
Open-Stop-Close function (J1.3 1/2-opening J1.4 full-opening)
Functionofexternalimpulsegenerators
1
51
Three-button-control
0*
Pulse input for Open-Stop-Close
6
Pulse input for (smoke-heat exhaust) (menu 55)
7
7
DU-settings
71
72
73
74
75
76
77
78
- -
Increasedclosingspeed
Speed in rpm
Closingspeed
Speed in rpm
Openingspeed
0*
20 - 30
20*
20 - 65
30*
Doorsettingchange-overpoint[73]to[72]
Speed in rpm20 - 30
Accelerationtimeclose
x 0.1 sec
Accelerationtimeopen
20*
05 - 30
20*
x 0.1 sec05 - 30
Brakingtimeclose
x 0.1 sec
Brakingtimeopen
20*
05 - 30
20*
x 0.1 sec05 - 30
Exit menu