TO REDUCE THE RISK OF INJURY, USER MUST READ AND
UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS
IMPORTANT INFORMATION REGARDING THE OPERATION AND
WARRANTY OF THIS PRODUCT. PLEASE RETAIN FOR FUTURE
REFERENCE.
OWNER’S MANUAL
3000W Power Inverter
Model number-4573000

Questions and Answers

  • C
    Christian NortonAug 16, 2025
    How to troubleshoot NPower 4573000 with no power and no indicator?
    • E
      Eileen TateAug 16, 2025
      If your NPower Inverter has no power and no indicator light, the possible causes are a defective battery, a blown fuse, or loose cable connections. To solve this, replace the battery if it's defective. Also, check and replace the fuse if it's blown. Finally, check the connection to the battery and tighten it as needed.
  • R
    Richard ChenAug 19, 2025
    What to do if NPower 4573000 Inverter shows OLP and shuts down?
    • R
      Rick ArmstrongSep 12, 2025
      If your NPower Inverter shuts down and the display shows 'OLP', it means an overload shutdown has occurred. This could be because the connected AC products are rated at more than 3000W or, the AC products are rated less than 3000W, but high starting surge has caused overload shutdown. To resolve this, reduce the load by using a product with a power rating of less than 3000W. Alternatively, use a product with a starting surge power within the inverter’s capability (≤5000W).
  • J
    James MolinaAug 21, 2025
    Why is the alarm sounding on my NPower 4573000?
    • E
      erin09Aug 21, 2025
      If the alarm is sounding on your NPower Inverter, it indicates that a low voltage shutdown or thermal shutdown has occurred. You can try the following to resolve the issue: * Shorten cables or use heavier cables. * Recharge the battery. * Allow the unit to cool. * Improve air circulation around the unit. * Move the unit to a cooler environment. * Reduce the load if continuous operation is required.
  • C
    Cameron WilliamsAug 25, 2025
    Why is the battery run time less than expected on my NPower 4573000?
    • L
      Lori WarnerAug 26, 2025
      If the battery run time of your NPower Inverter is less than expected, the causes could be: * AC product power consumption is higher than rated. * The battery is old or defective. * The battery is not being properly charged. * Power dissipation in DC cables. To address this, use a larger battery if the power requirement is increased. Replace the battery if it's old or defective. Ensure you're using a powerful charger to fully recharge the battery. Also, consider using shorter/heavier DC cables.
  • S
    Stephanie WrightAug 27, 2025
    What to do if NPower 4573000 Inverter shows OCP and shuts down?
    • J
      Justin GrossAug 27, 2025
      If your NPower Inverter shuts down and the display shows 'OCP', it means the inverter is overheated due to poor ventilation. To fix this, unplug the inverter from the DC socket and allow it to cool for 15 minutes. Remove any objects covering the unit and move the inverter to a cooler place. If continuous operation is required, reduce the load and restart the inverter.
  • M
    Mia CarterAug 31, 2025
    Why NPower 4573000 runs small loads but not large ones?
    • V
      Virginia NashAug 31, 2025
      If your NPower Inverter runs small loads but not large ones, it's likely due to a low voltage battery. To fix this, charge the battery.
  • A
    Amanda MontgomerySep 2, 2025
    What to do if NPower 4573000 shows LUP and shuts down?
    • L
      Linda DavisSep 3, 2025
      If your NPower Inverter shuts down and displays “LUP”, it indicates that the voltage input is too low, which triggers an alarm. To resolve this, charge the battery.
  • J
    Jorge WebbSep 6, 2025
    Why is the measured output too low on my NPower Inverter?
    • J
      Jennifer SnyderSep 6, 2025
      If the measured output of your NPower Inverter is too low, it may be because a standard “average-reading” AC voltmeter was used, resulting in an apparent reading 5 to 15V too low. The solution is to use a “true RMS” voltmeter for accurate measurements, as the inverter’s output is a “modified sine wave”.
  • M
    martinezmartinSep 8, 2025
    What to do if NPower Inverter shows OPP and shuts down?
    • K
      Kathy PrattSep 9, 2025
      If your NPower Inverter shuts down and the display shows “OPP”, it indicates a short circuit. To return to normal operation, use the manual switch to reset the inverter.
  • S
    Sydney BrownSep 12, 2025
    What to do if water entered my NPower 4573000 Inverter?
    • H
      Heather HardySep 12, 2025
      If water has entered your NPower Inverter, disconnect it immediately and wipe it with a dry cloth. Failure to do so can result in permanent damage due to liquid ingress.

Summary

Introduction

Important Safety Information

Protective Features

Over-input Voltage Shut off

Inverter shuts down if DC input voltage exceeds 15.5V.

Low-Input Voltage Shut off

Inverter shuts down if DC input voltage drops below 10.5V.

Low-input Voltage Alarm

Audible alarm sounds when DC input voltage drops below 11V.

Over-heating Shut Off

Inverter shuts down if internal temperature exceeds regulated temperature.

Overload Shut Off

Inverter shuts down if output power exceeds rated power or surge.

Short-circuit Protection

Unit switches to protective mode during a short circuit.

Features

Installation

Operating Instructions

Troubleshooting

Specifications

AC Output Specifications

Details AC output power, voltage, frequency, and waveform.

USB Output Specifications

Details USB output specifications.

DC Input Specifications

Details DC input voltage range, low battery alarm, and fuse.

Physical Specifications

Details operating temperature, dimensions, and weight.

Warranty

NPower 4573000 Specifications

General IconGeneral
Input Voltage12V DC
Output Voltage120V AC
Frequency60 Hz
Efficiency90%
ProtectionOverload, Over Voltage, Low Voltage