PCS-9785
Satellite-Synchronized Clock
Instruction Manual
NR Electric Co., Ltd.
08020
08020
08020
08020
08020
08020
08020
08020
08020

Table of Contents

Questions and Answers

  • S
    Sandra MoralesAug 20, 2025
    How to fix synchronization loss on satellite channel 1 for NR Electric PCS-9785 Clock?
    • D
      Daniel StanleyAug 20, 2025
      To address the synchronization loss on satellite channel 1 of your NR Electric Clock, verify the wiring between antenna 1 and the CLK module.
  • W
    wlopezAug 22, 2025
    How to troubleshoot antenna alarm on satellite channel 1 of NR Electric PCS-9785?
    • R
      rmitchellAug 22, 2025
      To resolve the antenna alarm on satellite channel 1 of your NR Electric Clock, check the installation of antenna 1 and its connection to the CLK module.
  • E
    Eric BaileyAug 25, 2025
    How to fix synchronization loss on satellite channel 2 for NR Electric PCS-9785?
    • L
      Lauren RiveraAug 25, 2025
      To address the synchronization loss on satellite channel 2 of your NR Electric Clock, check the wiring between antenna 2 and the CLK module.
  • M
    Michael SteeleAug 26, 2025
    How to troubleshoot antenna alarm on satellite channel 2 of NR Electric Clock?
    • C
      Clinton ScottAug 27, 2025
      To resolve the antenna alarm on satellite channel 2 of your NR Electric Clock, check the installation of antenna 2 and its connection to the CLK module.
  • S
    Sean ParsonsAug 28, 2025
    What to do if NR Electric PCS-9785 initialization fails?
    • J
      John CollinsAug 28, 2025
      If your NR Electric Clock experiences an initialization failure for a long time, check the external time source.
  • A
    Aaron WalterAug 30, 2025
    What to do if NR Electric Clock shows 'Send IRIG-B' alarm?
    • C
      castilloandrewAug 30, 2025
      If you encounter the 'Send IRIG-B' alarm on your NR Electric Clock, check the optical fiber connection for the IRIG-B sending link and inspect the CLK module.
  • M
    michelle71Sep 1, 2025
    How to fix 'Parity IRIG-B1' alarm on NR Electric PCS-9785 Clock?
    • K
      kyle67Sep 1, 2025
      To resolve the 'Parity IRIG-B1' alarm on your NR Electric Clock, unify the parity check mode of both the transmitter (TX) and receiver (RX) for the IRIG-B1 link.
  • D
    Daniel Nelson DDSSep 3, 2025
    How to fix 'Parity IRIG-B2' alarm on NR Electric Clock?
    • G
      Gregory PorterSep 3, 2025
      To resolve the 'Parity IRIG-B2' alarm on your NR Electric Clock, unify the parity check mode of both the transmitter (TX) and receiver (RX) for the IRIG-B2 link.
  • B
    blopezSep 5, 2025
    How to troubleshoot 'Receive IRIG-B1' alarm on NR Electric PCS-9785 Clock?
    • N
      Nancy PetersSep 5, 2025
      To resolve the 'Receive IRIG-B1' alarm on your NR Electric Clock, check the optical fiber connection for the IRIG-B1 reception link.
  • B
    Brenda Watson DDSSep 7, 2025
    How to troubleshoot 'Receive IRIG-B2' alarm on NR Electric Clock?
    • M
      Matthew BrownSep 7, 2025
      To resolve the 'Receive IRIG-B2' alarm on your NR Electric Clock, check the optical fiber connection for the IRIG-B2 reception link.

Summary

Preface

Introduction to the Manual

Provides overview of the guide and manual content for equipment operation.

Health and Safety Precautions

Details safety information for handling, installation, and operation of the equipment.

Instructions and Warnings

Defines symbols and general warnings for safe operation and maintenance.

Safety Precautions and Definitions

Defines DANGER, WARNING, CAUTION, NOTICE levels for safety communication.

Earthing and Operating Environment

Specifies requirements for earthing the device and suitable operating environments.

Product Specifications Overview

Briefly covers ratings, circuit boards, external circuits, and connection cables.

Documentation Structure

Outlines the organization of the manual, listing key chapters and their content.

Introduction to the Satellite-Synchronized Clock

Overview of the Satellite-Synchronized Clock

Provides a general description of the PCS-9785 clock and its role in SAS.

Key Features and Capabilities

Highlights the main features like remote supervision, time service, and accuracy.

Technical Data

Electrical Specification Details

Details power supply, voltage, and binary output specifications.

Mechanical Specification Details

Covers mounting, dimensions, weight, chassis material, and protection class.

Ambient Temperature and Humidity Range

Specifies operating and storage environmental conditions for the device.

Communication Port Specifications

Details Ethernet, SFP, EIA-485, and Optical port parameters.

Clock Synchronization Port Specifications

Lists input and output specifications for various synchronization ports.

Type Test Specifications

Details environmental, mechanical, insulation, and EMC test standards.

Synchronization Specifications

Provides detailed specs for PPS/PPM/PPH, IRIG-B, and network timing.

Certifications

Lists compliance certifications like ISO9001, ISO14001, OHSAS18001.

Operation Theory

Overview of Clock Operation

Explains the modular design and core functions: reception, time service, and output.

Redundancy Strategies

Details dual device redundancy, PRP, and HSR protocols for reliability.

Supervision

Supervision Alarms

Describes the device's self-monitoring capabilities and alarm generation.

Alarm Descriptions

Lists and describes various supervision alarms for device status.

Troubleshooting Alarms

Provides suggestions for resolving detected supervision alarms.

Hardware

Overview of Device Modules

Introduces the device's modular structure and components.

HMI Module Description

Details the Human Machine Interface module, its display, and keypad.

MON Module Description

Explains the Monitoring & Communication module's functions and ports.

CLK Module Description

Details the Satellite Signal Receiver (CLK) module and its variants.

COM Module Description

Describes various Communication (COM) modules and their interfaces.

PWR Module Description

Explains the Power Supply (PWR) module's function and connector.

Settings

Overview of Settings

Introduces the importance of correct configuration for device operation.

Clock Source Settings

Configures device settings, time zones, clock sources, NTP, PTP, and serial ports.

Clock Extension Settings

Covers settings for extension mode: current year, time, input modes, and alarms.

Human Machine Interface

HMI Overview and Design

Describes the HMI module's purpose, design, and user interaction.

HMI Keypad Functions

Explains the operation of each key on the HMI keypad for navigation and control.

HMI LED Indicators

Details the function of each LED indicator on the HMI panel.

HMI Debugging and Ethernet Ports

Explains the debugging port and Ethernet port setup for PC communication.

HMI Menu Tree Navigation

Illustrates the menu structure for accessing status, records, settings, and tests.

Installation

Installation Overview and Safety

Covers general installation guidelines and critical safety precautions.

Shipment Checking and Requirements

Details procedures for checking shipments and required materials/tools.

Device Location and Ambient Conditions

Specifies ideal placement and environmental conditions for device installation.

Mechanical Installation

Provides guidance on physical mounting, dimensions, and module insertion.

Electrical Installation and Wiring

Covers grounding, wiring, and antenna installation procedures.

Commissioning

Commissioning Overview and Safety

Provides an overview and safety instructions for the commissioning process.

Commissioning Tools and Preparation

Lists necessary tools and familiarization steps before commissioning.

Product Checks

Details checks for device integrity, function, and settings before operation.

Final Checks

Confirms device readiness, wiring, and reset states after commissioning tests.

Maintenance

Appearance Check and Failure Tracing

Guides on checking device appearance and tracing detected failures.

Failed Module Replacement

Provides step-by-step instructions for replacing faulty modules.

Cleaning and Storage

Details procedures for cleaning the device and storing spare modules.

Decommissioning and Disposal

Decommissioning Procedures

Outlines steps to safely switch off, disconnect cables, and dismantle the device.

Disposal Guidelines

Emphasizes compliance with local and national laws for device disposal.

Appendix

IRIG-B Time Code Format

Illustrates the structure and format of the IRIG-B time code.

Revisions History

NR Electric PCS-9785 Specifications

General IconGeneral
GPS ReceiverYes
BD ReceiverYes
IRIG-B InputYes
IRIG-B OutputYes
PPS OutputYes
PTP OutputYes
NTP OutputYes
TOD OutputYes
ManagementSNMP, Web
Mounting19-inch rack mount
Synchronization ModeGPS, BD, IRIG-B
Accuracy1μs
RedundancyDual power supply