This document serves as a hardware installation guide for NSFOCUS Security Products, covering various device types and models. It provides information on hardware appearance, technical specifications, installation procedures, and basic troubleshooting.

Function Description

NSFOCUS Security Products encompass a range of devices designed for network security, including Anti-DDoS Systems (ADS), Benchmark Verification Systems (BVS), Enterprise Security Planning Customer (ESPC), Network Intrusion Detection Systems (NIDS), Network Intrusion Prevention Systems (NIPS), Network Traffic Analyzers (NTA), NTA-D, NTA-FLB, Remote Security Assessment Systems (RSAS), Traffic Analysis Centers (TAC), Web Application Firewalls (WAF), and Web Vulnerability Scanning Systems (WVSS). These devices are available in portable, 1U, 2U, 4U, or 6U chassis, catering to diverse networking environments such as governments, enterprises, and carriers.

The core function of these devices is to provide robust security solutions, ranging from protection against distributed denial-of-service attacks, network intrusion detection and prevention, traffic analysis, remote security assessment, and web application protection. The specific capabilities vary by device model, but generally involve monitoring network traffic, identifying and mitigating threats, and ensuring the integrity and availability of network services.

Important Technical Specifications

The document details hardware parameters for numerous models across the product lines. Key specifications include dimensions (WDH), power supply type (single AC, redundant AC, or redundant DC), input voltage ranges, input current, and maximum output power, as well as the device weight.

ADS (Anti-DDoS System):

  • ADS NX3-800E (1U): 43039044 mm, 6.7 kg. Single AC power supply: 110–240 V input, 1.5–3 A current, 250 W max output.
  • ADS NX3-HD1000 (1U): 43545044 mm, 7.5 kg. Redundant AC power supply: 100–240 V input, 1.5–4 A current, 300 W max output.
  • ADS NX3-HD2500/NX5-HD4500 (1U): 43556044 mm, 8.65 kg. Redundant AC power supply: 100–240 V input, 2.5–5 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.
  • ADS NX5-HFA2000 (1U): 43556044 mm, 8.5 kg. Redundant AC power supply: 100–240 V input, 2–5 A current, 300 W max output. Redundant DC power supply also available: 100–240 V input, 300 W max output.
  • ADS NX3-2000E/NX5-4000E/NX5-6000E (2U): 57543288 mm, 13.8 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.
  • ADS NX5-HD6500/NX5-HD8500 (2U): 43556088 mm, 16 kg. Redundant AC power supply: 100–240 V input, 4.5–2 A current, 300 W max output.
  • ADS NX5-8000 (2U): 62644388 mm, 16.5 kg. Redundant AC power supply: 100–240 V input, 7–3 A current, 450 W max output. Redundant DC power supply also available: –36 V to +72 V input, 500 W max output.
  • ADS NX5-10000/NX5-12000 (6U): 482686266 mm, 40–72 kg. Redundant AC power supply: 85–264 V input, 7–3 A current, 850 W max output.

BVS (Benchmark Verification System):

  • BVS NX3-P (Portable): 27117544 mm, 2.35 kg. Single AC power supply: 100–240 V input, 1.6 A current, 60 W max output.
  • BVS NX3-S (1U): 43039044 mm, 6.7 kg. Single AC power supply: 110–240 V input, 1.5–3 A current, 250 W max output.
  • BVS NX3-E (2U): 57543288 mm, 12.6 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.

ESPC (Enterprise Security Planning Customer):

  • ESPC NX3-HD1000D/HD2000D/HD2200-BM (1U): 43556044 mm, 11 kg (HD1000D/HD2000D) or 12.7 kg (HD2200-BM). Redundant AC power supply (HD2200-BM): 100–240 V input, 5–2.5 A current, 300 W max output. AC power supply (HD1000D/HD2000D): 100–240 V input, 6–3 A current, 250 W max output.
  • ESPC NX3-HD3000D/HD5000D (2U): 43556088 mm, 20 kg. Redundant AC power supply: 100–240 V input, 4.5–2 A current, 300 W max output.

NIDS (Network Intrusion Detection System):

  • NIDS NX3-CH1330/CH1350/HD1200C/HD1300C/HD1600 (1U): 43039044 mm, 6.7 kg. Single AC power supply: 110–240 V input, 1.5–3 A current, 250 W max output.
  • NIDS NX3-HD4200/HD4300 (1U): 43556044 mm, 8.65 kg. Redundant AC power supply: 100–240 V input, 2.5–5 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.
  • NIDS NX3-CH3330 (2U): 57543288 mm, 12.6 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.
  • NIDS NX5-CH6330/CH6350 (2U): 62644388 mm, 16.5 kg. Redundant AC power supply: 100–240 V input, 7–3 A current, 450 W max output. Redundant DC power supply also available: –36 V to +72 V input, 500 W max output.
  • NIDS NX3-HD4220/HD4320/NX5-HD4500/HD4520/HD4700/HD4720/HD6200/HD6300 (2U): 43556088 mm, 16 kg. Redundant AC power supply: 100–240 V input, 4.5–2 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.
  • NIDS NX5-HD12000 (4U): 440176600 mm, 38.04–51.96 kg. Redundant AC power supply: 100–240 V input, 12–6 A current, 1200 W max output per power supply.
  • NIDS NX3-HFC/NX5-HFD (1U): 43556044 mm, 8.65 kg. Redundant AC power supply: 100–240 V input, 2.5–5 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.

NIPS (Network Intrusion Prevention System):

  • NIPS NX3-CH1330/CH1350/HD1200C/HD1300C/HD1600 (1U): 43039044 mm, 6.7 kg. Single AC power supply: 110–240 V input, 1.5–3 A current, 250 W max output.
  • NIPS NX3-HD4200/HD4300 (1U): 43556044 mm, 8.65 kg. Redundant AC power supply: 100–240 V input, 2.5–5 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.
  • NIPS NX3-CH3330 (2U): 57543288 mm, 12.6 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.
  • NIPS NX5-CH6330/CH6350 (2U): 62644388 mm, 16.5 kg. Redundant AC power supply: 100–240 V input, 7–3 A current, 450 W max output. Redundant DC power supply also available: –36 V to +72 V input, 500 W max output.
  • NIPS NX3-HD4220/HD4320/NX5-HD4500/HD4520/HD4700/HD4720/HD6200/HD6300 (2U): 43556088 mm, 16 kg. Redundant AC power supply: 100–240 V input, 4.5–2 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.
  • NIPS NX5-HD12000 (4U): 440176600 mm, 38.04–51.96 kg. Redundant AC power supply: 100–240 V input, 12–6 A current, 1200 W max output per power supply.
  • NIPS NX3-HFC/NX5-HFD (1U): 43556044 mm, 8.65 kg. Redundant AC power supply: 100–240 V input, 2.5–5 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.

NTA (Network Traffic Analyzer):

  • NTA NX3-C1000E/1000E/2000E (2U): 57543288 mm, 13.8 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.
  • NTA NX3-HD2100/HD2200 (2U): 43556088 mm, 16 kg. Redundant AC power supply: 100–240 V input, 4.5–2 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.

NTA-D:

  • NTA-D NX3-2000E (2U): 57543288 mm, 13.8 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.
  • NTA-D NX3-HD3000 (2U): 43556088 mm, 16 kg. Redundant AC power supply: 100–240 V input, 4.5–2 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.

NTA-FLB:

  • NTA-FLB NX3-F2000 (2U): 57543288 mm, 13.8 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.
  • NTA-FLB NX3-F2200 (2U): 43556088 mm, 16 kg. Redundant AC power supply: 100–240 V input, 4.5–2 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.

RSAS (Remote Security Assessment System):

  • RSAS NX3-P (Portable): 27117544 mm, 2.35 kg. Single AC power supply: 100–240 V input, 1.6 A current, 60 W max output.
  • RSAS NX3-A (Portable): 32422062 mm, 3.8 kg. Single AC power supply: 100–240 V input, 2 A current, 150 W max output.
  • RSAS NX3-X (1U): 43039044 mm, 5 kg. Single AC power supply: 100–240 V input, 0–5 A current, 65 W max output.
  • RSAS NX3-S (1U): 43039044 mm, 6.7 kg. Single AC power supply: 110–240 V input, 1.5–3 A current, 250 W max output.
  • RSAS NX3-E (2U): 57543288 mm, 12.6 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.

TAC (Traffic Analysis Center):

  • TAC NX3-D600A/D1000A/D2000A/E600A/E1000A/E2000A (2U): 62644388 mm, 16.5 kg. Redundant AC power supply: 100–240 V input, 7–3 A current, 450 W max output. Redundant DC power supply also available: –36 V to +72 V input, 500 W max output.
  • TAC NX3-D200A (2U): 57543288 mm, 12.6 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.

WAF (Web Application Firewall):

  • WAF NX3-HD300C/HD600C/HD800C (1U): 43039044 mm, 5 kg. Single AC power supply: 100–240 V input, 0–5 A current, 65 W max output.
  • WAF NX3-P1000B (2U): 57543288 mm, 12.6 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.
  • WAF NX5-CH7650 (2U): 62644388 mm, 16.5 kg. Redundant AC power supply: 100–240 V input, 7–3 A current, 450 W max output. Redundant DC power supply also available: –36 V to +72 V input, 500 W max output.
  • WAF NX5-HD1600/HD1610/HD1620/HD1630 (2U): 43556088 mm, 16 kg. Redundant AC power supply: 100–240 V input, 4.5–2 A current, 300 W max output. Redundant DC power supply also available: –36 V to +72 V input, 300 W max output.
  • WAF NX3-P1000E/P2000A/NX5-P2020A/P1600E/CH5630/CH5650 (2U): 57543288 mm, 13.8 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.
  • WAF NX5-HF6000D/HF (2U): 56043588 mm, 17 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 460 W max output.
  • WAF NX3-HF (1U): 56043544 mm, 13 kg. Redundant AC power supply: 100–240 V input, 1.5–3 A current, 120 W max output.

WVSS (Web Vulnerability Scanning System):

  • WVSS NX3-P (Portable): 27117544 mm, 2.35 kg. Single AC power supply: 100–240 V input, 1.6 A current, 60 W max output.
  • WVSS NX3-X (1U): 43039044 mm, 5 kg. Single AC power supply: 100–240 V input, 0–5 A current, 65 W max output.
  • WVSS NX3-S (1U): 43039044 mm, 6.7 kg. Single AC power supply: 110–240 V input, 1.5–3 A current, 250 W max output.
  • WVSS NX3-E (2U): 57543288 mm, 12.6 kg. Redundant AC power supply: 100–240 V input, 8–5 A current, 350 W max output. Redundant DC power supply also available: –36 V to +72 V input, 400 W max output.

The devices feature various ports including RJ45 console ports, USB ports, management ports (M, H, H1), working/expansion ports (electrical and optical), and in some cases, IPMI ports and VGA ports for monitors. LEDs on the front panel indicate power (PWR), system status (SYS), hard disk drive activity (HDD), link/activity (Link/Act), bypass function, CMM status (A/S), and BIOS submission status.

Usage Features

The installation process for NSFOCUS Security Products follows a structured procedure:

  1. Installation Preparations: This involves checking the accessory kit against the packing list, ensuring all necessary components (cables, rackmount accessories, rubber pads, bolts, nuts, screws) are present. User-provided tools like screwdrivers, multimeters, ESD wrist straps, and tape are also required. The installation environment must meet specific temperature (0°C–45°C) and humidity (10%–95% non-condensing) requirements, be dust-proof, and have proper grounding. The rack must be secure and compatible with the device.
  2. Mounting onto the Rack:
    • 1U Devices: Involves installing front mounting ears with bolts, then installing rack rails at the rear of the cabinet with nuts and screws, and finally mounting the device onto the installed rails.
    • 2U Devices: Similar to 1U devices, but with more bolts for front mounting ears (eight in total) and rack rails.
    • 6U Devices: These are distributed rack-mounted devices with interface and service boards. The number of AC power supply modules varies based on the number of service boards (e.g., 2 power supplies for 1 service board, 3 for 2 service boards, 4 for 3 service boards, and 5 for 4, 5, or 6 service boards).
  3. Connecting the Power Cable:
    • AC Power Cable: Ensure the device is grounded, turn the power switch to OFF, connect the power cable to the device and the equipment room socket, then turn the power switch to ON. Verify the power LED on the front panel is on.
    • DC Power Cable: For devices with Positronic connectors or binding posts, ensure the power switch is OFF. For Positronic connectors, insert the –48 V DC power supply lead wires into the jacks of the DC power supply socket. For binding posts, connect the positive (+) lead wire (black) to the cathode and the negative (–) lead wire (red) to the anode. Insert the DC power plug and tighten screws. For dual power supplies, repeat the process for the second cable.
  4. Connecting the Network Cable: Connect one end of the Ethernet cable to the electrical port on the device and the other end to the peer device. A green network port LED indicates a successful connection.
  5. Shutting Down the Device: For most devices, turn the power switch to OFF. For devices with momentary switches, press and hold the button until the power LED turns off.

The devices offer various working/expansion port configurations, including combinations of electrical, optical, and 10G ports, or empty slots, allowing for flexible network integration.

Maintenance Features

The document provides a basic troubleshooting guide for common issues:

  1. Check Web-based Manager Login: If login is possible, check system, engine, interface, and traffic status. If an interface is DOWN, check physical connections (network and power cables) and LEDs (PWR, STA, network card). If nothing abnormal, contact NSFOCUS support. If system, engine, or traffic status is abnormal, restart and try console login.
  2. Check Console Login: If console login is possible, check system, engine, interface, and traffic status. If an interface is DOWN, check physical connections and LEDs. If nothing abnormal, contact NSFOCUS support. If system, engine, or traffic status is abnormal, fix based on the error message.
  3. If Login is Not Possible:
    • Layer 2 Transparent Deployment: Bypass the security device by directly connecting uplink and downlink devices to restore network connectivity and services.
    • Layer 3 Routing or Out-of-Path Diversion/Injection Mode: Remove the device from the network without affecting routing and services to see if network and services resume.
    • In-Path Transparent Deployment: Switch the device to debugging mode so traffic bypasses the detection engine.
    • Persistent Network Interruption: If the fault persists, power off the device. If the network resumes, the fault is likely due to incorrect device configurations.
  4. Contact Support: If the problem persists or a device/interface failure is confirmed, contact NSFOCUS technical support.

LED indicators provide visual cues for device status:

  • Power LED (PWR): On (working), Off (unavailable/not working).
  • Status LED (STA): Blinking (reading/writing data), Off (idle).
  • Hard Disk Drive LED (HDD): Blinking (reading/writing data), Off (idle/not inserted).
  • Running LED (RUN): On (working).
  • System LED (SYS): Off (unavailable/not working), Orange (high CPU usage), Red (too high CPU usage).
  • Link/Act LED: Green (link established), Off (no link). Yellow (blinking for transmitting/receiving data), Off (no data).
  • Bypass LED: On (bypass enabled), Off (bypass disabled).
  • CMM Status LED (A/S): On (CMM activated), Off (CMM waiting).
  • Status LED (+): Red (BIOS submission in progress), Green (BIOS submission completed).
  • Status LED (STAT): Green (device works properly), Orange (engine works improperly).
  • Status LED (MGR): Green (switch board works properly).
  • Status LED (ACTN): On (Orange) (IPMI connection normal), Off (IPMI connection not set up).

The document also includes notes on product disposal, emphasizing the importance of delivering end-of-life products to qualified recycling stations in accordance with national laws and regulations, and avoiding methods explicitly phased out by the government.

NSFOCUS ADS NX3-800E Specifications

General IconGeneral
BrandNSFOCUS
ModelADS NX3-800E
CategoryNetwork Hardware
LanguageEnglish