Select a Humidity Setting
PRESS THE UP OR DOWN ARROW KEY UNTIL THE PRESENT HUMIDITY SETTING AND % SYMBOL ARE FLASHING. USE THE UP/DOWN
ARROW BUTTONS TO ADJUST HUMIDITY SETTING IN 5% INCREMENTS. AFTER 4 SECONDS OF NO BUTTON ACTIVITY, SELECTED
HUMIDITY SETTING (SETPOINT) WILL BE PROGRAMMED.THE CURRENT AMBIENT HUMIDITY WILL THEN BE DISPLAYED.
WHEN AMBIENT HUMIDITY EXCEEDS THE CHOSEN SETPOINT A WATER DROP ICON WILL APPEAR AND THE VENTILATOR WILL
OPERATE IN HIGH SPEED UNTIL THE HUMIDITY LEVEL DROPS BELOW SETPOINT. AVAILABLE HUMIDITY SETTING RANGE: 20-80%.
TO TURN OFF HUMIDITY-ACTIVATED HIGH SPEED IF DESIRED, USE THE ARROW KEYS TO TOGGLE THE HUMIDITY SETPOINT TO
ONE CLICK ABOVE 80% OR ONE CLICK BELOW 20%. ALSO USE ARROW KEYS TO REACTIVATE HUMIDITY CONTOL.
00: OFF. VENTILATOR IS OFF, BUT THE CONTROL ITSELF IS ON AND WILL DISPLAY AMBIENT HUMIDITY
LEVEL.
01: STANDBY. VENTILATOR IS IDLE. DURING THIS MODE, A STATIC PAUSE ICON WILL DISPLAY. DURING STANDBY MODE THE VENTILATOR WILL
TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR A TIMER.
02: LOW SPEED. VENTILATOR RUNS IN LOW SPEED CONTINUOUSLY. DURING THIS MODE, AN ANIMATED 3-BLADE FAN WILL DISPLAY. DURING
LOW SPEED MODE THE VENTILATOR WILL TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR A TIMER.
03: HIGH SPEED. VENTILATOR RUNS IN HIGH SPEED CONTINUOUSLY. DURING THIS MODE, AN ANIMATED 6-BLADE FAN WILL DISPLAY. VENTILATOR
WILL REMAIN IN HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR A TIMER AND CONTINUE IN HIGH SPEED AFTER THE
HUMIDITY/TIMER DEMAND IS MET.
04: 20 LO/40 STANDBY. VENTILATOR CYCLES CONTINUOUSLY BETWEEN 20 MINUTES OF LOW SPEED OPERATION AND 40 MINUTES OF STANDBY
OPERATION. DURING LOW SPEED CYCLE, THE FAN 3-BLADE FAN ICON WILL ANIMATE AND THE PAUSE SYMBOL WILL FLASH TWICE EVERY 5 SECONDS.
DURING THE STANDBY CYCLE, THE PAUSE ICON WILL BE STATIC AND THE FAN ICON WILL FLASH TWICE EVERY 5 SECONDS. DURING 20 LO/40 STANDBY
MODE THE VENTILATOR WILL TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR A TIMER.
05: RECIRCULATION. VENTILATOR CONTINUOUSLY RECIRCULATES AIR WITHIN THE HOME AND DOES NOT BRING IN AIR FROM OUTSIDE, I.E. AIR
EXCHANGE DOES NOT OCCUR. DURING THIS MODE AN ANIMATED CYCLING ARROW WILL DISPLAY. DURING RECIRCULATION MODE THE
VENTILATOR WILL TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND FROM THE LUMINA HUMIDITY SENSOR OR AN EXTERNAL TIMER.
Recirculation Modes
NOTE TO INSTALLER: FOR MODELS OF VENTILATOR THAT DO NOT HAVE RECIRCULATION COMPONENTS, TURN OFF RECIRCULATION FUNCTIONS THE
OPTIONS MENU (SEE CUSTOM SETTINGS).
06: 20 LO/40 RECIRCULATION. VENTILATOR CYCLES CONTINUOUSLY BETWEEN 20 MINUTES OF LOW SPEED OPERATION AND 40 MINUTES OF
RECIRCULATION OPERATION. DURING THE LOW SPEED CYCLE, THE FAN WILL ANIMATE AND THE RECIRCULATION RING WILL FLASH TWICE
EVERY 5 SECONDS. DURING THE RECIRCULATION CYCLE, THE RECIRCULATION ARROW WILL ANIMATE AND THE FAN ICON WILL FLASH TWICE
EVERY 5 SECONDS. DURING 20 LO/40 RECIRCULATION MODE THE VENTILATOR WILL TEMPORARILY SWITCH TO HIGH SPEED ON DEMAND
FROM THE LUMINA HUMIDITY SENSOR OR A TIMER.
OPERATING HINT. GENERALLY, A HUMIDITY SETTING OF 40-60% IS DESIRABLE. WHILE YOUR VENTILATOR IS NOT A DEHUMIDIFIER, VENTILATION CAN
HAVE THE EFFECT OF REDUCING INDOOR HUMIDITY WHEN EXCHANGING MOISTURE-LADEN AIR FROM THE INTERIOR SPACE WITH LESS HUMID, FRESH
AIR FROM OUTSIDE, ESPECIALLY DURING COLDER MONTHS.
Modes