EasyManua.ls Logo

NuAire NU-430-600 User Manual

NuAire NU-430-600
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
OM0228 Page1of99
February/2014
LabgardESEnergySaverClassII,
TypeB2LaminarFlow
BiologicalSafetyCabinet
Models
NU430400/600
Bench/Console
Operation&MaintenanceManual
February,2014
(Series65)
Revision1



ManufacturedBy:
NuAire,Inc.
2100FernbrookLane
Plymouth,MN55447
TollFree:18003283352
InMinnesota:(763)5531270
Fax:(763)5530459

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the NuAire NU-430-600 and is the answer not in the manual?

NuAire NU-430-600 Specifications

General IconGeneral
BrandNuAire
ModelNU-430-600
CategoryAir Conditioner
LanguageEnglish

Summary

General Information

1.2 Safety Instructions

Outlines critical safety instructions for operating the cabinet.

Models & Features

Installation Instructions

5.1 Location

Recommends ideal placement away from air currents for optimal performance.

5.2 Set-Up Instructions

Covers unpacking, base stand assembly, leveling, and bench installation steps.

5.2.6 Electrical Services

Covers electrical connection requirements, safety, and GFCI recommendations.

5.4 Certification Testing Methods and Equipment

Details methods and equipment for certifying the cabinet's performance.

Operating the NU-430

6.1 Biological Safety Cabinet Control

Describes the cabinet's control system, interface, and functions like blower, lights, and alarms.

6.2 Operating Guidelines

Presents general guidelines for safe and effective cabinet use, covering work area, air curtain, and aseptic technique.

6.3 Operating Sequence

Details the step-by-step sequence for operating the cabinet, including startup and shutdown procedures.

6.6 Hazardous Drug Decontamination Procedures

Outlines procedures for decontaminating the cabinet after hazardous drug use, including PPE.

General Maintenance

7.1 Decontamination

Explains procedures for decontaminating the cabinet before performing maintenance.

7.3 HEPA Filter/Motor Replacement

Details the process for replacing HEPA filters and motors, emphasizing filter type and handling.

7.5 Airflow Control System Setup and Calibration

Covers setting up and calibrating the airflow control system, including setpoints and sensors.

7.5.3 Airflow Calibration

Explains the process of balancing airflow and calibrating sensors for accurate readings.

Error Messages, Troubleshooting, Option-Diagnostics & Airflow Sensor Performance Verification

8.1 Error Message Troubleshooting Guide

Provides guidance for troubleshooting various error messages and their corresponding corrections.

Electrical/Environmental Requirements