EasyManua.ls Logo

NuAire NU-475-600 User Manual

NuAire NU-475-600
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
OM0196
CELLGARD ES Energy Saver Class II,
Type A2 Laminar Flow
Biological Safety Cabinet
Models
NU-475-300/400/500/600
Bench/Console
Operation & Maintenance Manual
January, 2011
Revision 1
(Series 1 & Higher)
Manufactured by:
NuAire, Inc.
2100 Fernbrook Lane
Plymouth, Minnesota USA 55447
Toll Free: 1-800-328-3352
In MN: 763-553-1270
Fax: 763-553-0459
NU-475-400/500/600 Only
Question and Answer IconNeed help?

Do you have a question about the NuAire NU-475-600 and is the answer not in the manual?

NuAire NU-475-600 Specifications

General IconGeneral
UV LightOptional
BrandNuAire
ModelNU-475-600
ClassClass II
MotorECM motor
Electrical Requirements115V AC or 230V AC
ApplicationLaboratory

Summary

General Information

Safety Instructions for Operation

Outlines critical safety precautions and procedures for operating the safety cabinet.

Installation Instructions

Cabinet Location Guidelines

Recommends ideal placement for the biological safety cabinet within a laboratory.

Set-Up and Initial Placement

Covers the initial steps for unpacking and positioning the cabinet.

Electrical Services and Final Assembly Steps

Details on electrical needs and final setup steps.

Certification Testing Methods

Outlines the tests required for cabinet certification and commissioning.

Operating the NU-475 Cabinet

Operator Controls and Indicators Overview

Describes the function of each control and indicator on the cabinet's front panel.

Airflow Calibration and Monitoring

Details how to calibrate airflow using the potentiometer and the minihelic gauge.

Operating Guidelines

Defining the Safe Working Area

Identifies the designated safe zone for performing work within the cabinet.

Operating Sequence Procedures

Material Placement and Work Execution

Guidelines for arranging materials and performing tasks safely.

Hazardous Drug Decontamination

Hazardous Drug Decontamination Procedure

Provides a detailed, step-by-step process for decontaminating the cabinet.

General Maintenance

HEPA Filter and Motor Replacement

Airflow Calibration and Adjustment

Cabinet Airflow Calibration

Explains the process of balancing airflow within the cabinet for optimal performance.

Airflow Testing Procedures

HEPA Filter Leak Testing

Procedures for testing the integrity of HEPA filters and their seals.

Site Installation Assessment Tests

Pharmacy Application Cleanliness Testing

Error Indicators and Troubleshooting

Troubleshooting Common Errors

A guide to identifying and resolving common error indicators and operational issues.

Electrical and Environmental Requirements