EasyManuals Logo

Nyos Quantum Series User Manual

Nyos Quantum Series
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
EN
No skimming
action
- run-in period of the device
- water level in the skimmer is
too low
- water level in the sump is too
low
- pump is clogged, dirty, has
lime scale deposits
- the venturi system is clogged
- feed containing grease, water
additives, nutrient solutions
- adjust settings (see pp.
14-15)
- use activated carbon,
change water
- wait a few days
- discontinue feed contai-
ning grease, water additi-
ves, nutrient solutions
- clean pump and mail to
service if needed
Pump too
noisy
- run-in period of the device
- pump is dirty or has lime
scale deposits, foreign object in
pump
- hybrid wheel unit is damaged
- rotor is not properly positioned
in pump
- filter tank is too small or skim-
mer touches the side panel of
the sump. Then, the filter tank
functions as sound box and can
increase the noise of the pump.
- adjust settings (see pp. 14-
15) and wait a few days
- open and clean pump (see
pp. 16-17)
- mail pump to service
- position the skimmer freely
- select a larger filter cham-
ber
Micro-bub-
bles in the
outlet
- run-in period of the device
- water throughput too high
- water level in the sump is too
high
- adjust settings (see pp. 14-
15) and wait a few days
- turn the water level control
tube further, turn the micro-
adjustment screw for the
water level further (if nee-
ded, adjust the air capacity).
19

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nyos Quantum Series and is the answer not in the manual?

Nyos Quantum Series Specifications

General IconGeneral
CategoryProtein Skimmer
SeriesQuantum
ManufacturerNyos
Body MaterialAcrylic
Adjustable Air IntakeYes
Pump TypeNeedle Wheel
SilencerIncluded
TypeIn-Sump